Pelco DX8000 ユーザーズマニュアル

ページ / 96
76
C623M-C (3/05)
Appendix D: Connecting an Uninterruptible Power Supply (UPS)
If uninterrupted operation is desired and the power grid cannot provide adequate uptime, it is highly recommended that each DX8000 Series DVR 
be connected to a UPS device (not supplied). A UPS device will supply a limited amount of battery backup power in the event of a power failure. 
Each UPS device should be configured to shut down its corresponding DVR safely during an extended period on battery power.
UPS TO DVR COMMUNICATION AND POWER CONNECTIONS
1. Shut down the DX8000. Refer to 
2. Connect the UPS to the DX8000 using a standard USB cable.
3. Connect the other end of the USB cable to one of the four USB 2.0 ports on the back panel of the DVR.
4. Connect the power cord of the UPS to a standard wall socket.
5. Connect the power cord of the DX8000 to one of the power outlets on the UPS.
6. Turn the UPS device power switch on.
7. Turn the DX8000 power switch on.
Figure 86.  UPS to DX8000 Connections
IMPORTANT:  Only those UPS devices that exhibit the Designed for Microsoft Windows XP logo and are listed on the Windows 2000 
Hardware Compatibility List are approved for use with the DX8000 Series DVR.
WARNING:  Do not install on the DX8000 any power management software that may come with your UPS device. The DX8000’s operating 
system includes built-in services designed to communicate with UPS devices that exhibit the Designed for Microsoft Windows XP logo.
NOTE:  The following instructions are meant as a general guide for connecting a UPS device to the DX8000 Series DVR. The example 
below illustrates the installation of an American Power Conversion UPS. This guide is not intended as a representation of how to install 
every possible make and model of UPS device. Follow the directions that came with your UPS device to ensure that the installation process 
is completed properly.
IN1
IN2
IN3
IN4
IN5
IN6
IN7
IN8
IN9
IN10
IN11
IN12
IN13
IN14
IN15
IN16
OUT16
OUT15
OUT14
OUT13
OUT12
OUT11
OUT10
OUT9
OUT8
OUT7
OUT6
OUT5
OUT4
OUT3
OUT2
OUT1
ALARM INPUTS
RELAY OUTPUTS
1
2 2 4 5 6 7 8 GND
9 10 11 12 13 14 15 16
1
2 2 4 5 6 7 8 GND
9 10 11 12 13 14 15 16
CRT
POWER
CONNECTION
POWER
CONNECTION
UPS
RS-232
USB CABLE