Freedom F-64 Installation Instructions 
WI1501A  9/06 
 
Page 17
 
GLOSSARY 
The Freedom 64 control panel is capable of utilizing a combined total of 7 keypads and/or Touchpads, with a maximum of 4 Free-
dom Touchpads assigned to addresses 1-4.  The balance can be any of NAPCO's Gemini "K Series" keypads assigned to ad-
dresses 5-7.  (Note:  Any Gemini "K Series" keypads installed in the system would possess limited functionality, and should only be 
used to view system status).  Displayed messages shown are for the Freedom Touchpads and Gemini "K Series" keypads.  Please 
refer to the F-64 Programming Manual (WI1502) for specific address numbers.  Please note that the definitions in this glossary that 
refer to "keypads" only apply to installations using Gemini "K Series" keypads on addresses 5-7.   
 
Abort Delay (Do not program for UL Applications) 
An Abort Delay is a delay period that allows cancellation of the central-station report by disarming the control panel before a report is 
sent.  If Enable CP-01 Limits is enabled, the Abort Delay is 30 seconds (which cannot be removed but can be adjusted to within the CP-
01 specification of 15-45 seconds).  In addition, if an attempt is made to change the Abort Delay to less than 15 seconds or more than 
45 seconds, the time will be entered as 30 seconds.  If enable CP-01 Limits is NOT enabled, the factory delay time will be set at 30 sec-
onds, and can be deleted or increased to 255 seconds.  See glossary entry Enable CP-01 Limits.  Enable program zones for Abort 
Delay 
and select an Abort Delay Time.  Also, a Pre-Alarm Warning may be selected for zones allowing a Touchpad indication of alarm 
with no alarm outputs or central station reporting for the duration of abort delay time.   
 
AC Failure; AC-Fail Report Delay 
If AC power is removed from the control panel, "
AC POWER FAIL/E01-00 SERVICE
" will display at the Touchpad with a flashing 
"
SYS TBL
" icon as a reminder and a pulsing sounder.  Press RESET  to silence the sounder; the "
SYS TBL
" icon reminder will remain 
on and "
SYSTEM READY
" will appear in the display.  If a User Code is entered within 5 minutes, the panel may be armed.  After 5 
minutes, the system trouble will again display. 
AC Failure may be programmed to activate the Alarm OutputPulsed Alarm OutputPGM1 OutputPGM2 OutputRelay Outputs and/
or report to a central station by selecting AC Fail Report Event Telco 1AC Fail Report Restore Telco 1AC Fail Report Event Telco 3
AC Fail Report Restore Telco 3.  The AC Trouble Fail Display, AC Fail Logging, and AC Fail Report to the central station will occur 
immediately unless an AC Fail Report Delay is programmed. 
 
Access Control; Access Control (Panel Access) on PGM2 Output; PGM2 Output Access Control Time; Panel Access 
The following refers to the F-64PROG programmer only: 
Note: 
The F-64 panel has not been evaluated by UL for compliance with UL294 (Access Control Systems). 
The PGM2 Output can be programmed to activate for a programmable period of time (2 to 254 sec.).  This allows it to be used for 
access functions such as opening and closing a garage door, or remotely activating an electric door strike through an RB1000 relay.  
This is achieved by programming a new Keyfob option, Access on PGM2 Output, into the Aux. 1 or Aux. 2 option locations on the 
Wireless Keyfobs screen.  This feature also requires a valid time to be entered into the PGM2 Output Access Control in the Time 
Selection Screen. 
If Access Control on PGM2 Output is selected, entering the Access Code (see User Code Programming in Easy Menu Driven Program 
Mode) while disarmed will trip the panel's PGM2 Output.  (This is commonly used to activate a door strike for the purposes of remotely 
unlocking a door).  Each keypad is individually selected for Panel Access.  Also program PGM2 Output Access Control Timeout.  Note:  
Do not program the PGM2 Output as an output on alarm.  Do not program Keyfob Chirp on PGM2, unless Enable Bell Output on RF 
Arming 
is selected also. 
Panel Access is selectable for any keypad 1–7 by selecting the appropriate Area Option of any User Code (see User Code 
Programming in Easy Menu Driven Program Mode); select the Panel Access option for those keypad numbers (1–7) that are to 
respond to the User Code.  However, if the Access Option is programmed, the code will no longer function as an Arm/Disarm Code.   
Entering a valid code at the keypad will cause the PGM2 output on panel to turn on for the programmed time.  The RB1000 Relay may 
be used to activate a door strike, and power to the door strike should be supplied from an independent power source. 
 
Access Number for Outside Line (CS Receiver Telephone Number Access) 
Some subscribers will have a telephone system that requires one digit to access an outside line.  The first dial tone encountered (prior 
to the access number) may have a frequency that is different from that of the accessed dial tone (440Hz).  One or more 4-second Pre-
Dial Delay "D"s may be entered before any of the CS Receiver Telephone Numbers instead of a dial tone with frequency "E".  See Pre-
Dial Delay; Telephone Numbers.  (Note:  The panel features automatic dial-tone detection and will normally not require any "E"s.  To 
disable this feature, see CS System Report Options in the Programming Instructions WI1502). 
If the subscriber's system uses an access number, contact the telephone-equipment supplier to find out if a dial tone other than 440Hz 
is received prior to dialing the access number.  If the communicator must delay before dialing the access number instead of attempting 
to recognize the dial tone, find out how many 4-second delays must be programmed. 
 
Alarm on Day Zone  See Day Zone 
 
Alarm Outputs (See Wiring Diagram for UL requirements); Alarm Output Duration 
The F-64 has three outputs: Alarm (Burg. & Fire), PGM1 and PGM2.  The following table summarizes wiring for signaling an alarm in 
typical installations.  See Time Selection for timeout durations. 