Heath Zenith SH-5318 ユーザーズマニュアル

ページ / 8
Models SH-5318
D
ual
B
rite
®
Motion Sensor
Light Control with
2-Level Lighting
© 2007 HeathCo LLC 
598-1154-01
2 Shells*
Features
•  Turns on lighting when motion is detected.
•  Automatically turns lighting off.
•  D
ual
B
rite
®
 Timer.
•  Photocell keeps the lighting off during daylight hours.
•  LED indicates motion was sensed (day or night).
* Model SL-5318 only
This package includes:
Light Control
Sensor
Cover Plate
Lamp Holders
Plastic Hanger
Rubber Plug
Gasket
6 Screws
(3 sizes included)
Mounting Strap
Mounting Bolt
2 Wire
Connectors
Requirements
•  The light control requires 120-volts AC.
•  If you want to use Manual Mode, the control must be 
wired through a switch.
• 
Some  codes  require  installation  by  a  
qualified electrician.
•  This product is intended for use with the enclosed 
gasket and with a junction box marked for use in wet 
locations.
TEST
TEST  1 5 20
ON-TIME
Off  3  6  Dusk to
 
    Dawn
D
ual
B
rite
®
Put  ON-TIME  switch 
on the sensor bottom 
to TEST and the D
ual
-
B
rite
®
 switch OFF.
OPERATION
* resets to Auto Mode at dawn.
ON-TIME
TEST 
1 5 20
... back on.
1 Second OFF 
then...
Put the ON-TIME switch in the 1, 5, 
or 20 minute position.
Manual  mode  only  works  at  night 
because daylight returns the sensor 
to AUTO.
Flip the light switch off for one second 
then back on to toggle between AUTO 
and MANUAL MODE.
Manual  mode  works  only  with  the 
ON-TIME  switch  in  the  1,  5,  or  20 
position.
Note:  When first turned on wait about 1 
1
/
2
 minutes for 
the circuitry to calibrate.
Mode:
On-Time
Works: Day Night
Test
5 Seconds
x
x
Auto
1, 5, or 20 Min
x
Manual
To Dawn*
x
Accent
3, 6 Hr, to Dawn
x
AUTO
MANUAL MODE
D
ual
B
rite
®
 Timer
Light comes on half bright for selected time after dusk 
(Off, 3 hr., 6 hr., until dawn). Selecting OFF disables 
this feature. The motion sensing features will continue 
to work as described in this manual. If motion is sensed, 
the light turns on full bright for the ON-TIME (1, 5, or 
20 minutes) then returns to dim mode.
Move ON-TIME Switch to 
1, 5, or 20 minutes
Mode Switching Summary
Flip light switch off 
for one second then 
back on*
MANUAL MODE
AUTO
TEST
*  If you get confused while switching modes, turn the 
power off for one minute, then back on. After the cali-
bration time the control will be in the AUTO mode.