Note:  A 4-channel Charger must be used with a 4-channel Base Station and an 8-channel Charger 
must be used with an 8-channel Base Station for an express pair to be successful.  
Power Module 
The Charger Base requires 9-24VDC power, provided by the AC Adapter. Plug the supplied AC 
adapter into an appropriate power outlet 110-240 AC, 50-60Hz. The power LED on the Charger Base 
will illuminate. 
 
Charging the Microphone Batteries 
 
First-time use  —  Before using the wireless microphone the first time, charge the batteries in the 
microphones for eight hours (or overnight) in the Charger Base. 
 
Recharging — When the YELLOW LED starts to flash intermittently on the microphone the battery 
has 30 minutes of charge remaining. Over time (years), batteries gradually wear down and require 
longer charging times. This is normal. Always return microphones to the Charger Base when not in 
use. 
ImportantThe Lithium Polymer rechargeable batteries that power the microphones are not user 
serviceable. Please contact Revolabs (www.revolabs.com) or your AV service provider for 
replacement instructions and to assure the proper disposal method is used. Warning: Never 
dispose of batteries in a fire because they may explode.
 
Either a solid RED LED (charging) or solid GREEN LED (100% charged) will appear to confirm that 
the microphone is inserted properly in the Charger Base. The microphones are not transmitting audio 
to the Executive HD base  station while in the Charger Base. In normal use, batteries should fully 
charge in about 2 hours, but will “quick-charge” to 80% capacity in approximately 1 hour and 20 
minutes. Fully charged microphones left in the Charger Base remain solid GREEN. 
 
Updating the Revolabs HD
TM
 Firmware 
 
Executive HD Systems are  field upgradable for the firmware portion of the Base Station and 
microphones. The firmware must be sent to both  the Base station and microphone using the HD 
Control Panel program.  
 
Note:   If your Base Station and microphones have different firmware versions, they may not work 
together. Confirm that your Base Station and microphones are updated before use.  
 
Updating the Executive HD Base Station & Microphones 
The Executive HD Base Station firmware can be changed using the Revolabs HD Control Panel 
program.  You  can download the latest firmware at 
.  The same 
firmware file can be used for all Revolabs HD
TM
 Products. Communication to the Base Station is done 
over  an  Ethernet connection, and communication to the microphones is done through the Charger 
Base via Mini-USB cable.