Heath Zenith 5318 ユーザーズマニュアル

ページ / 20
© 2007 HeathCo LLC 
595-5731-07
Models 5312 and 5318
D
ual
B
rite
®
 Motion Sensor 
Light Control
TEST
2 Shells*
Features
•  Turns on lighting when motion is detected.
•  Automatically turns lighting off.
•  D
ual
B
rite
®
 Timer.
•  Photocell keeps the lighting off during daylight hours.
•  LED indicates motion was sensed (day or night).
TEST  1 5 20
ON-TIME
Off  3  6  Dusk to
 
    Dawn
D
ual
B
rite
®
Put  ON-TIME  switch 
on the sensor bottom 
to TEST and the D
ual
-
B
rite
®
 switch OFF.
OPERATION
* resets to Auto Mode at dawn.
ON-TIME
TEST 
1 5 20
... back on.
1 Second OFF 
then...
Put the ON-TIME switch in the 1, 5, 
or 20 minute position.
Manual  mode  only  works  at  night 
because daylight returns the sensor 
to AUTO.
Flip the light switch off for one second 
then back on to toggle between AUTO 
and MANUAL MODE.
Manual  mode  works  only  with  the 
ON-TIME  switch  in  the  1,  5,  or  20 
position.
Note:  When first turned on wait about 1 
1
/
2
 minutes for 
the circuitry to calibrate.
This package includes:
Light Control
Sensor
Cover 
Plate
Bulb 
Holders
Plastic Hanger
Rubber Plug
Gasket
6 Screws
(3 sizes included)
Mounting Strap
Mounting Bolt
2 Wire
Connectors
Requirements
•  The light control requires 120-volts AC.
•  If you want to use Manual Mode, the control must be 
wired through a switch.
• 
Some  codes  require  installation  by  a  
qualified electrician.
•  This product is intended for use with the enclosed 
gasket and with a junction box marked for use in wet 
locations.
Meets the ENERGY STAR
®
 guidelines 
when  D
ual
B
rite
®
  function  is  off  and 
ON-TIME is 1 or 5 minutes and when 
used with 120 W Max bulbs.
Mode:
On-Time
Works: Day Night
Test
5 Seconds
x
x
Auto
1, 5, or 20 Min
x
Manual
To Dawn*
x
Accent
3, 6 Hr, to Dawn
x
AUTO
MANUAL MODE
* Model SL-5318 only