Avaya 03-300430 ユーザーズマニュアル

ページ / 2574
DS1-FAC (DS1 Facility)
Issue 1 June 2005
1061
 
Clearing Firmware Errors
DS1 converter error reports are generated by firmware autonomously. DS1 converter error 
reports are not associated with technician-demanded tests. The test board clear 
command does not affect the error status known by the DS1 converter firmware. To clear every 
on-board firmware-detected error unconditionally, use clear firmware-counters.
Error Log Entries and Test to Clear Values
Table 364: DS1 Facility Error Log Entries
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
SAT Test to Clear Value
0 (
0
Any
Any
Any
test ds1-facility location sh r 1
1 (
Failure Audit #949
MAJ
ON
test board location sh r 1
18 (
)
0
busyout 
ds1-facility 
location
WRN
OFF
release ds1-facility location
257 (
Failure Audit #949
MIN
ON
test board location sh r 1
513 (
1
Failure Audit #949
MIN
OFF
test board location sh r 1
513 (
2
Failure Audit #949
MIN
OFF
test board location sh r 1
856 (
DS1 Facility Query for 
Slips/Misframes #972
MIN
OFF
none
1025 (
Failure Audit #949
MAJ
1
1. These failures are logged as a WRN alarm when the error is first reported. The alarm severity is raised to a 
MAJOR in 15 minutes if the problem persists.
OFF
test board location sh r 1
1281 (
None
Failure Audit #949
MAJ
OFF
test board location sh r 1
1281 (
1
Failure Audit #949
MAJ
OFF
test board location sh r 1
1281 (
2
Failure Audit #949
MAJ
OFF
test board location sh r 1
1537 (
Failure Audit #949
MAJ
OFF
test board location sh r 1
1793 (
Failure Audit #949
MAJ
OFF
test board location sh r 1
2065 (
)
DS1 Facility Query for 
Slips/Misframes #972
MIN
OFF
none
2305 (
Failure Audit #949
MAJ
OFF
test board location sh r 1
2561 (
Failure Audit #949
OFF
test board location sh r 1