Avaya 03-300430 ユーザーズマニュアル
Denial Event Tables
Issue 1 June 2005
181
1058
Auto Callback User ID
User activating automatic callback has software
partyblock member misrepresented.
1059
Auto Callback double qued
User is activating automatic callback, but the call
has already been queued or has no principal
terminating User ID.
1060
Auto Callback terminator
Activating automatic callback is not allowed when
the terminating extension is a group attendant,
terminating extension group, Vector Directory
Number, or if vector processing is active.
1061
Auto Callback terminator
Activating automatic callback.
●
For a non-Distributed Communication
System (DCS) terminator, if there is an
accompanying Call Detail Recording
(CDR) ineffective call attempt record, the
queue is full or zero-length.
●
For a DCS terminator, termination did not
happen for one of several reasons
identified in rc from gm_term
re_termination attempt in onhk_que.c
1062
Auto Callback activation
Activating automatic callback. Checks on queue
availability and/or Distributed Communication
System (DCS) termination pass OK, but activation
is denied.
1063
Auto Callback ineligible
Activating Automatic Callback (ACB). Response
to callback type query is queue ineligible, might be
ACB is in use or call is on hold, or GQRY_ERR
(might be no call ID behind call back button).
1064
Double queueing denied
Manual activation of queueing. Call has already
been queued (automatic).
1065
Manual queing terminator
Manual activation of queueing. There is no
principal terminator on which to queue.
1066
Manual queing - full que
Manual activation of queueing. The queue is full
or queue length is zero.
1067
Manaual queing denied
Manual activation of queueing. Checks on queue
availability pass OK, but activation is denied.
1068
queued call went away
Reactivation of automatic callback or outgoing
trunk queueing. The call disappeared from the
queue.
1069
PMS link/printer down
Property Management System (PMS) cannot log
housekeeping status. PMS link is not operational
and the printer is down.
1070
(also in
TTR_unavail
ISDN trunk initiation of in-band end-to-end digit
collection failed. Might be waiting for a Touch Tone
Receiver (TTR).
1071
Wireless - trunk failure
General Central Office (GCO) Wireless
Subscriber System (WSS) call origination denied -
iap_cid_qry failure. Route to GCO subscriber
trunk failed.
Table 48: Call Process denial events (1001 - 1172) (continued)
Event
Type
Type
Event Description, as it
appears on the event log
appears on the event log
Explanation
Event
Data 1
Data 1
Event Data 2