Avaya 03-300430 ユーザーズマニュアル
TIE-TRK (Analog Tie Trunk)
Issue 1 June 2005
2309
1002
ABRT
The system could not allocate time slots for the test. The system may be
under heavy traffic conditions or it may have time slots out-of-service due
to TDM-BUS errors.
under heavy traffic conditions or it may have time slots out-of-service due
to TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy
traffic, repeat test at 1-minute intervals up to 5 times.
1003
ABRT
The system could not allocate a tone receiver for the test. The system
may be oversized for the number of Tone Detectors present or some
Tone Detectors may be out-of-service.
may be oversized for the number of Tone Detectors present or some
Tone Detectors may be out-of-service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the test at 1-minute intervals up to 5
times.
1004
ABRT
The port was seized by a valid call during the test. The test has been
aborted. Use display trunk-group xx to determine the trunk group/
member number of the port. Use status trunk to determine the service
state of the port. If the service state indicates that the port is in use, then
the port is unavailable for certain tests. Wait until the port is idle before
retesting.
2000
ABRT
Response to the test request was not received within the allowable time
period.
period.
1. Retry the command at 1-minute intervals up to 5 times.
2100
ABRT
Could not allocate the necessary system resources to run this test. This
could be due to a failure to seize the port.
could be due to a failure to seize the port.
1. Retry the command at 1-minute intervals up to 5 times.
Table 829: Test #6 NPE Crosstalk Test (continued)
Error
Code
Code
Test
Result
Result
Description / Recommendation
2 of 3