Avaya 03-300430 ユーザーズマニュアル
M/T-DIG (Maintenance/Test Digital Port)
Issue 1 June 2005
1711
Notes:
a. Error Type 0: run the short test sequence first. If every test passes, run the long test
sequence. Refer to each test’s description, and follow its procedures.
b. Error Type 1: there was a hardware failure on a digital port’s circuitry. Replace the
Maintenance/Test circuit pack if the alarm is not resolved by the command above.
c. Error Type 18: the port was busied out by busyout port location.
d. Error Type 257: the Maintenance/Test digital port is talking on more than just its assigned
time slot. Replace the Maintenance/Test circuit pack.
e. Error Type 513: the Maintenance/Test digital port has failed its self-test. Because the Digital
Port Sanity test runs only on port 2, but tests both ports 2 and 3, both ports are alarmed
when the test fails. The command indicates to test port 2, even if the error is logged against
port 3.
when the test fails. The command indicates to test port 2, even if the error is logged against
port 3.
f. Error Type 769: the Maintenance/Test digital port was unable to successfully loop data from
a tone generator to a tone detector.
g. Error Type 3840: call processing records do not agree with on-board records for the hook
state (on-/off-hook) of the Maintenance/Test digital port. This error is not service-affecting
and no action is required.
and no action is required.
257 (
Any
NPE Crosstalk test
(#9)
MIN
ON
test port location l r 3
513 (
Any
Digital Port Sanity
test (#565)
MIN
ON
test port location r 2
769 (
Any
Digital Port Loop
Around test (#13)
MIN
ON
test port location r 3
3840 (
) Any
Hook State Inquiry
test (#566)
Table 632: M/T-DIG Error Log Entries (continued)
Error
Type
Type
Aux
Data
Data
Associated Test
Alarm
Level
Level
On/Off
Board
Board
Test to Clear Value
2 of 2