D9112B | Program Entry Guide | 1.0  Panel Wide Parameter 
EN | 18 
 
 
Bosch Security Systems | 2/04 | 74-06145-000-D 
 
Ph# Test/Stat Rpt 
Default: 
Blank 
Selection: 
Blank, P, B, or D 
See the introduction to Phone Routing for a 
description of the selections. 
Test
 reports and 
Status
 reports are enabled in the 
Skeds section of the program. For 
Test
 reports, see 
Sked Function Code #9. For 
Status
 reports, see 
Sked Function Code #10. 
Test
 and 
Status
 reports are identified at the D6500 
using the account number for Area 1. 
If 
Expand Test Rpt
 in Phone is YES, the 
Test
 report 
includes additional system events, if the panel is 
currently in one of these conditions: 
Prog Access 
OK, SDI Failure, Comm Failure, Battery 
Missing, Battery Low, Pt Bus Trouble, 
AC Failure, Params Bad Cksm, Log 
Threshold, Log Overflow, Bad Call to 
RAM, and User Tamper
After a 
Reset-Bye or disable restart, the panel 
checks to see if the following conditions exist. If they 
do, the panel sends appropriate reports with the test 
report: 
Log
 
Threshold
Log
 
Overflow
Bad Call 
to RAM
, and 
User Tamper
. All other system events 
are cleared and do not report at test time. 
To clear 
Bad Call to RAM
 and 
User Tamper
 
events, simply contact the panel with RAM II. To 
clear 
Log Threshold
 and 
Log Overflow
 
contact the panel with RAM II and perform a 
Receive Log and Set Pointer function from the 
Logger menu. 
Ph# Diagnostic 
Default: 
Blank 
Selection: 
Blank, P, B, or D 
See the introduction to Phone Routing for a 
description of the selections. 
If a Parameter Checksum Fail (
Parm Cksum Fail
report is received, the user can silence the panel’s 
buzzer, but cannot clear the system trouble display. 
To correct a Parameter Checksum Fail condition, re-
load the program into the panel using RAM or the 
D5200 
Ph# Relay 
Default: 
Blank 
Selection:  Blank, P, B, or D 
See the introduction to Phone Routing for a 
description of the selections. 
Ph# Skeds 
Default: 
Blank 
Selection:  Blank, P, B, or D 
See the introduction to Phone Routing for a 
description of the selections. 
Note:  
The panel uses Skeds 18 to 49 for opening and closing 
windows and 
Skeds 50 to 64 for User Access 
Windows. Routing 
Skeds activity to a receiver when 
using these features can result in excessive receiver 
traffic. 
Ph# RAM 
Default: 
Blank 
Selection: 
Blank, P, B, or D 
See the introduction to Phone Routing for a 
description of the selections. 
These events are associated with RAM functions. 
RAM reports are identified at the D6500 using the 
account number for Area 1. 
RAM Access Fail 
may indicate a wrong 
passcode when communicating with the panel, or a 
valid RAM session was terminated by a means other 
than a 
Good-bye or Reset-bye command. 
Log 
Threshold
 is programmed in RAM Parameters 
Log 
% Full
Remote Reset
 indicates a 
Reset-Bye 
command issued from RAM. 
Bad Call to RAM
 
indicates that the panel called RAM but was unable 
to connect. 
Ph# Power/Phone 
Default: 
Blank 
Selection:  Blank, P, B, or D 
See the introduction to Phone Routing for a 
description of the selections.