D9112B | Program Entry Guide | 3.0  User Interface 
EN | 51 
 
 
Bosch Security Systems | 2/04 | 74-06145-000-D 
 
L## Perim Inst 
Perimeter Instant Arm 
Default: 
See Training Sheet 
Selection: 
Blank or E 
Blank 
Disable this function for Authority Level (L##) specified, if this Command Center Function item 
requires a passcode (P). 
Enable this function for Authority Level specified. When the passcode is entered at the command 
center, the panel checks the authority level. The panel executes the function only in areas where the 
passcode is authorized. 
Programming in O/C Options Perimeter O/C determines whether Perimeter Closing reports can be 
generated for a particular area. 
Whether Perimeter Closing reports and subsequent Opening reports are generated by this user or 
not depends on the L## Perimeter O/C prompt in Authority Lvl Assign
Perim Delay 
Perimeter Delay Arm [COMMAND] [3]: 
This command center function arms all perimeter points (see Point Index 
Point Type
) in the 
area where the 
command center is assigned. No entry or exit delays are provided with this arming function. 
Default: 
Blank 
Selection: 
Blank, E, or P 
Blank 
Disable the function panel-wide. Accessing the function using a command, the Command Menu, or 
a custom function, displays 
NO AUTHORITY
Enable the function panel-wide. The function can be executed without entering a passcode. 
Programming in O/C Options 
Perimeter O/C
 determines whether 
Perimeter
 
Closing
 reports can 
be generated for a particular area. 
Passcode required. When the passcode is entered at the command center, the panel checks the 
authority level. The panel only arms the area if the passcode is authorized. 
 
0101
0101
0101
 
 
Force Arming: If a passcode is not required to arm this function, all authority levels can force arm. To 
disable force arming in an area, enter 0 in FA Bypass Max in the Area Parameters section of the program.