D9112B | Program Entry Guide | 3.0  User Interface 
EN | 55 
 
 
Bosch Security Systems | 2/04 | 74-06145-000-D 
 
Send Report 
Default: 
Selection: 
Blank, E, or P 
Send Report [COMMAND] [4] [1] and 
[COMMAND] [4] [2]: 
Test the communications link between the panel and 
the central station receiver(s). It can send a 
Test
 
report or a 
Status
 report to the phone numbers as 
programmed in Phone Routing. The 
Test
 report 
includes additional information if 
Expand Tst Rpt
 is 
enabled in the Phone section. 
0101
0101
0101
 
 
Test/Stat Rpt in Phone Routing must be 
programmed with a primary destination. If no 
routing is programmed for the report, the 
command center displays 
SENDING 
REPORT
 but the confirming message 
REPORT SENT
 never displays. 
This is a 
panel-wide function that can be executed 
from any command center assigned to an area where 
the user has authority. 
See Command Center Function Selections in the 
introduction to the Command Center Functions 
programming module for descriptions of selections. 
L## Send Report 
Default: 
See 
Program Record Sheet
 
Selection: 
Blank or E 
Send Report: See Authority Level Selections in the 
introduction to the Authority Lvl Assign programming 
module for descriptions of selections. 
Chg Display 
Default: 
Selection: 
Blank, E, or P 
Change Display [COMMAND] [4] [9]: 
This command center function affects only the 
command center address where the function is 
entered. The user can select either a bright or dim 
display with loud or soft command center warning 
tones, 
Chg Display
 also turns on the continuous 
time and date display. (The time and date display 
clears when a higher priority message needs to be 
displayed.) 
See Command Center Function Selections in the 
introduction to the Command Center Functions 
programming module for descriptions of selections. 
L## Chg Display 
Default: 
See 
Program Record Sheet
 
Selection: 
Blank or E 
Change Display: See Authority Level Selections in the 
introduction to the Authority Lvl Assign programming 
module for descriptions of selections. 
Chg Time/Date 
Default: 
Selection: 
Blank, E, or P 
Change Time and Date [COMMAND] [4] [5]: 
Set the time and date in the panel. This is a 
panel-
wide function that can be executed from any 
command center with the scope to view an area 
where the user has authority to perform this 
function. 
See Command Center Function Selections in the 
introduction to the Command Center Functions 
programming module for descriptions of selections. 
L## Chg Time/Date 
Default: 
See 
Program Record Sheet
 
Selection: 
Blank or E 
Change Time and Date: See Authority Level 
Selections
 in the introduction to the Authority Lvl 
Assign 
programming module for descriptions of 
selections. 
Chg Passcode 
Default: 
Selection: 
Blank or P 
Change Passcodes [COMMAND] [55]: 
Change the passcode numbers for users already 
programmed into the panel. This is a 
panel-wide 
function that can be executed from any command 
center assigned to an area where the user has 
authority. 
If you enter 
E, the panel treats the entry as P. 
See Command Center Function Selections in the 
introduction to the Command Center Functions 
programming module for descriptions of selections.