D9112B | Program Entry Guide | 3.0  User Interface 
EN | 58 
 
 
Bosch Security Systems | 2/04 | 74-06145-000-D 
 
Bypass a Pt 
Default: 
Selection: 
Blank, E, or P 
Bypass a Point [COMMAND] [0]: Bypass points in 
areas within the 
Scope
 of the command center 
where the function is entered (see Cmd Cntr 
Assignment
). Bypassed points do not respond to faults. 
See Command Center Function Selections in the 
introduction to the Command Center Functions 
programming module for descriptions of selections. 
L## Bypass a Pt 
Default: 
See 
Program Record Sheet
 
Selection: 
Blank or E 
Bypass a Point: See Authority Level Selections in the 
introduction to the Authority Lvl Assign programming 
module for descriptions of selections. 
Unbypass a Pt 
Default: 
Selection: 
Blank, E, or P 
Unbypass a Point [COMMAND] [0] [0]: Unbypass 
points in areas within the 
Scope
 of the command 
center where the function is entered (see Cmd Cntr 
Assignment
). When unbypassed, a point can detect 
faults and respond according to programming. 
See Command Center Function Selections in the 
introduction to the Command Center Functions 
programming module for descriptions of selections. 
L## Unbypass a Pt 
Default: 
See 
Program Record Sheet
 
Selection: 
Blank or E 
Unbypass a Point: See Authority Level Selections in 
the introduction to the Authority Lvl Assign 
programming module for descriptions of selections. 
Reset Sensors 
Default: 
Selection: 
Blank, E, or P 
Reset Sensors [COMMAND] [4] [7]: Activate the 
Reset Sensors function in areas within the 
Scope
 of 
the command center where the function is entered 
(see Cmd Cntr Assignment). See Relays section for 
information about Reset Sensors relay activation. 
See Command Center Function Selections in the 
introduction to the Command Center Functions 
programming module for descriptions of selections. 
L## Reset Sensors 
Default: 
See Training Sheet 
Selection: 
Blank or E 
Reset Sensors: See Authority Level Selections in the 
introduction to the Authority Lvl Assign programming 
module for descriptions of selections. 
Relay Control 
Default: 
Selection: 
Blank, E, or P 
Relay Control [COMMAND] [5] [4]: Manually 
operate relays installed in the D9112 system. This is 
panel-wide function that can be executed from 
any command center assigned to an area where the 
user has authority. See the D9112 Operation and 
Installation Manual
 for information about optional 
relays. 
See Command Center Function Selections in the 
introduction to the Command Center Functions 
programming module for descriptions of selections. 
L## Relay Control 
Default: 
See 
Program Record Sheet
 
Selection: 
Blank or E 
Relay Control: See Authority Level Selections in the 
introduction to the Authority Lvl Assign programming 
module for descriptions of selections. 
Remote Program 
Default: 
Selection: 
Blank, E, or P 
Remote Programming [COMMAND] [4] [3]: 
Initiate Remote Account Manager (RAM) sessions. 
This is a 
panel-wide function that can be executed 
from any command center assigned to an area where 
the user has authority. Reports concerning the 
remote programming session are generated as Area 
1 events. 
See Command Center Function Selections in the 
introduction to the Command Center Functions 
programming module for descriptions of selections.