L## Passcode Arm 
Determines the user’s ability to arm the panel 
without having to use the Command menu or an 
arming command. When enabled for an authority 
level, users with that authority level can arm the area 
by entering their passcode. 
If a bell is ringing in any area within the 
Scope
 of 
the command center and you enter a passcode, it 
silences the bell but does not arm the area. 
Default: 
See 
Program Record Sheet
 
Selection:  Blank or E 
Blank 
The user cannot arm the area by 
entering their passcode. 
NO 
AUTHORITY
 displays if the passcode is 
entered while the command center is 
displaying idle text. 
The user can arm the area by entering 
their passcode. 
To send 
Closing
 reports for users with 
this authority level 
A# Area O/C 
must 
be programmed YES in Open/Close 
Options
L## Area O/C
 must be 
enabled for this authority level. 
L## Passcode Disarm 
Determines the user’s ability to disarm the panel 
without having to use the menu structure. When 
enabled for an authority level, users with that 
authority level can disarm the area by entering their 
passcode. 
If a bell is ringing in any area within the 
Scope
 of 
the command center and you enter a passcode, it 
silences the bell and disarms the area. 
Default: 
See 
Program Record Sheet
 
Selection:  Blank or E 
Blank 
The user cannot disarm the area by 
entering their passcode. 
NO 
AUTHORITY
 displays if the passcode is 
entered while the command center is 
displaying idle text or the area is in 
entry delay. 
The user can disarm the area by 
entering their passcode. 
To send 
Opening
 reports for users with 
this authority level 
A# Area O/C
 must 
be programmed YES in Open/Close 
Options
L## Area O/C
 must be 
enabled for this authority level. 
4.0 Command 
Menu 
Use this programming category to create a list of 
functions that appear in command center displays 
when the user presses the [ESC]/[MENU] key while 
the command center is displaying idle text. The 
Command menu is customized according to 
command center address. 
Each command center address can display a unique 
list of functions to suit the application. For example, 
command centers with Address 1 may be located in 
a secure area. Therefore, you want to enable all 32 
function displays. But command centers with 
Address 2 may be located in a part of the building 
where you do not want casual access to any 
functions. Disabling all of the function displays 
forces the user at Address 2 to initiate all functions 
using commands. 
Area assignment and scope have no impact on 
which functions appear in the Command Menu, 
however these functions may affect the way that the 
functions operate when selected from the list. 
Menu Item 
Default: 
Selection: 
1 to 32 
Enter the menu item number you are programming. 
Do not skip over menu item numbers. Do not leave 
M## Function
 blank within the sequential list. 
When the panel reaches a 
Menu Item
 with a blank 
Menu Function
, it stops looking for more menu 
items. 
M## Function 
Default: 
See 
Program Record Sheet
 
Selection: 
Blank, 1 to 35 and 128 to 143 
Enter the Command Center Function number you 
want to appear in at least one command center 
display. Use the D9112 Program Record Sheet to 
determine function number. 
Function numbers 1 to 35 are shown in the first 
column on the User Interface Command Function page 
of the D9112 Program Record Sheet. The function 
name is shown in the second column labeled 
“Function.” The function name appears in the 
command center display as the user advances 
through the Command Menu.