3 Maintenance
3.1 Air Filter
The Phoenix FireBird is equipped with a pleated fabric air 
filter that must be checked regularly. The standard filter 
is a MERV- high efficiency filter. Operating the FireBird 
with a dirty or obstructed filter will reduce airflow eventually 
causing the heating element to shut off.  Installing a clean 
filter or removing the obstruction to restore airflow will 
allow the heating element to operate again.
The filter can generally be vacuumed clean several times 
before needing replacement. Replacement filters can be 
ordered from the factory or purchased locally if available.
WARNING: DO NOT operate the unit without the filter or 
with a less effective filter as the heating coils inside the 
unit could become clogged and require disassembly to 
clean.
4 Service
WARNING: Servicing the Phoenix FireBird with its high 
voltage circuitry presents a health hazard which could 
result in death, serious bodily injury, and/or property 
damage. Only qualified service people should service this 
unit.
Do not operate the unit without the front panel in place. 
High voltage is present, heater burnout may result.
4.1 Technical Description
The Phoenix FireBird uses a two stage wound nichrome 
heating element to provide two heat settings depending on 
application requirements or available power.  One element 
provides low power operation and both elements together 
provide high power operation.  The heating elements and 
the blower are operated by a 24VAC control circuit and a 
number of relays and contactors.  For safety, there is an 
air pressure switch that will shut the heating elements off 
or prevent the heating elements from coming on if airflow 
is restricted at either the inlet or the outlet.  An additional 
safety switch limits the incoming air temperature to 
40°F.  This switch shuts off the heating elements and 
automatically resets when the temperature falls to 00°F.
4.2 Troubleshooting
NOTE: High Power setting requires an external 50A circuit.  
Connecting to a 30A circuit with unit set to High Power will 
result in an external circuit breaker trip.
4
www.usephoenix.com • sales@thermastor.com
Toll-Free 1-800-533-7533
Blower not running
.  Unit unplugged, no power to outlet
2.  Power switch not working or set to “THERMOSTAT” and 
no thermostat connected, or thermostat not calling for 
heat
3.  Blower Relay not operating
4.  Wiring fault inside device
5.  Defective blower or blower capacitor
Blower running but no heat
.  Airflow restricted at inlet or outlet
2.  High temperature limit reached (40°F)
3.  Heating contactor(s) not operating
4.  Wiring fault inside device
5.  Defective heating element, pressure switch, or 
temperature limit switch
5 Options and Accessories
4024750 
2” x 25’ Intake Flex Duct
4024969 
6” x 20” x 2” Pleated Media MERV-8
402475 
6” x 20” x 2” Standard Pleated Media MERV-
402264 
6” x 20” x 2” Optional Pleated Media MERV-4
4027326 
25’ Cord Kit
4027327 
Thermostat Kit 
4024440 
Kestrel 3000 Multi-Meter