Desa GG30P ユーザーズマニュアル

ページ / 32
www.desatech.com
114683-01B
18
BURNER FLAME PATTERN
 WARNING: If yellow tipping 
occurs, your heater could pro-
duce increased levels of carbon 
monoxide.
NOTICE: Do not mistake orange 
flames with yellow tipping. Dirt 
or other fine particles enter the 
heater  and  burn  causing  brief 
patches of orange flame. 
Figure 25 shows a correct burner flame pattern. 
Figure 26 shows an incorrect burner flame pattern. 
The incorrect burner flame pattern shows yellow 
tipping of the flame. It also shows the flame higher 
than 1/2 the heat shield height.
If burner flame pattern is incorrect, as shown in 
Figure 26
•  turn heater off (see To Turn Off Gas To Appli-
ance, page 16 or 17)
•  see Troubleshooting, page 20
INSPECTING HEATER
Check pilot flame pattern and burner flame pat-
tern often.
PILOT FLAME PATTERN
Figure  23  shows  a  correct  pilot  flame  pattern. 
Figure 24 shows an incorrect pilot flame pattern. 
The  incorrect  pilot  flame  is  not  touching  the 
thermocouple. This will cause the thermocouple 
to cool. When the thermocouple cools, the heater 
will shut down.
If pilot flame pattern is incorrect, as shown in 
Figure 24
•  turn heater off (see To Turn Off Gas to Appli-
ance, page 16 or 17)
•  see Troubleshooting, page 20
Note:
 The pilot flame on natural gas units will 
have a slight curve, but flame should be blue and 
have no yellow or orange color.
Figure 24 - Incorrect Pilot Flame Pattern
Figure 23 - Correct Pilot Flame Pattern
Thermocouple
Pilot Burner
Pilot 
Burner
Thermocouple
Blue Flame
Yellow Flame
Figure 25 - Correct Burner Flame Pattern 
Yellow 
Tipping
Figure 26 - Incorrect Burner Flame 
Pattern 
Heat
1
/
2
  
 Shield
Height
Blue 
Flame
Heat
1
/
2
  
 Shield
Height