Desa GG30P ユーザーズマニュアル

ページ / 32
www.desatech.com
114683-01B
23
 WARNING: If you smell gas
•  Shut off gas supply.
•  Do not try to light any appliance.
•  Do not touch any electrical switch; do not use any phone in your 
building.
•  Immediately call your gas supplier from a neighbor’s phone. Fol-
low the gas supplier’s instructions.
•  If you cannot reach your gas supplier, call the fire department.
IMPORTANT:
 Operating heater where impurities in air exist may create odors. Cleaning supplies, 
paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. 
POSSIBLE CAUSE
1. Heater burning vapors from 
paint,  hair  spray,  glues,  etc. 
(see IMPORTANT statement 
above)
2. Low fuel supply (propane/LP 
gas only)
3. Gas  leak.  See  Warning 
statement above
1. Not  enough  fresh  air  is 
available
2. Low line pressure
3. ODS/pilot  is  partially 
clogged
1. Gas  leak.  See  Warning 
statement above
2. Control valve defective
1. Foreign matter between con-
trol valve and burner
2. Gas  leak.  See  Warning 
statement above
1. Not enough combustion/ven-
tilation air
OBSERVED PROBLEM
Heater  produces  unwanted 
odors
Heater  shuts  off  in  use  (ODS 
operates)
Gas odor even when control knob 
is in OFF position
Gas odor during combustion
Moisture/condensation  noticed 
on windows
REMEDY
1. Ventilate  room.  Stop  using 
odor causing products while 
heater is running
2. Refill supply tank
3. Locate and correct all leaks 
(see Checking Gas Connec-
tions, page 13)
1. Open window and/or door for 
ventilation
2. Contact local natural or pro-
pane/LP gas company
3. Clean ODS/pilot (see Cleaning 
and Maintenance, page 19) 
1. Locate and correct all leaks 
(see Checking Gas Connec-
tions, page 13)
2. Replace control valve
1. Take  apart  gas  tubing  and 
remove foreign matter
2. Locate and correct all leaks 
(see Checking Gas Connec-
tions, page 13)
1. Refer to Air for Combustion 
and Ventilation requirements 
(page 5)
TROUBLESHOOTING
Continued