Ventilation Air From Outdoors
Provide  extra  fresh  air  by  using  ventilation 
grills or ducts. You must provide two perma-
nent openings: one within 12" of the ceiling 
Or 
Remove 
Door into 
Adjoining 
Room, 
Option 3
Ventilation Grills 
Into Adjoining Room,
Option 2
12"
12"
Ventilation
Grills into
Adjoining
Room, 
Option 1
Figure 2 - Ventilation Air from Inside 
Building
Outlet
Air
Ventilated
Attic 
Outlet
Air
Inlet
Air
Inlet Air
Ventilated 
Crawl Space
To 
Crawl
Space
To Attic
Figure 3 - Ventilation Air from Outdoors
AIR FOR COMBUSTION AND VENTILATION
Continued
INSTALLATION
and one within 12" of the floor. Connect these 
items directly to the outdoors or spaces open 
to the outdoors. These spaces include attics 
and crawl spaces. Follow the National Fuel 
Gas  Code,  ANSI  Z223.1/NFPA  54,  Air  for 
Combustion and Ventilation
 for required size 
of ventilation grills or ducts.
IMPORTANT:  Do  not  provide  openings  for 
inlet or outlet air into attic if attic has a thermo-
stat-controlled power vent. Heated air entering 
the attic will activate the power vent.
NOTICE: This heater is intended 
for  use  as  supplemental  heat. 
Use this heater along with your 
primary heating system. Do not 
install  this  heater  as  your  pri-
mary heat source. If you have a 
central heating system, you may 
run system’s circulating blower 
while using heater. This will help 
circulate the heat throughout the 
house. In the event of a power 
outage, you can use this heater 
as your primary heat source.
 WARNING: A qualified ser-
vice person must install heater. 
Follow all local codes.
CHECK GAS TYPE
Use only the correct type of gas (natural or 
propane/LP).  If  your  gas  supply  is  not  the 
correct  gas  type,  do  not  install  heater.  Call 
dealer  where  you  bought  heater  for  proper 
type heater.
 WARNING: This appliance is 
equipped for either natural gas 
or propane/LP gas but not both. 
Gas type is indicated on the rat-
ing plate. Field conversion is not 
permitted.
INSTALLATION ITEMS
Before installing heater, make sure you have 
the items listed below.
•  for  propane/LP  gas,  external  regulator 
(supplied by installer)
•  piping (check local codes)
•  sealant (resistant to propane/LP gas)
•  equipment shutoff valve *
•  ground joint union
•  sediment trap
•  tee joint
•  pipe wrench
•  for natural gas, test gauge connection*
* A  CSA  design-certified  equipment  shutoff 
valve with 1/8" NPT tap is an acceptable al-
ternative to test gauge connection. Purchase 
the optional CSA design-certified equipment 