Desa RLP155AT ユーザーズマニュアル

ページ / 44
www.desatech.com
113855-01A
10
TROUBLESHOOTING
 WARNING: Never service heater while it is plugged in, connected 
to propane supply, operating, or hot. Severe burns and electrical 
shock can occur. 
REMEDY
1. Check  voltage  to  electrical 
outlet.  If  voltage  is  good, 
check heater power cord for 
breaks
2. Adjust  motor/fan  guard  to 
keep fan from hitting inside of 
heater shell. Bend fan guard if 
necessary
3. Replace fan. See Fan, page 8
4. Replace  motor.  See  Motor
page 7
1. Repeat installation and opera-
tion instructions. See Installa-
tion and Operation, page 5
2. A) Check ignitor wire. Tighten 
or reattach loose ignitor wire. 
See  Figure  11,  page  8  for 
ignitor wire location
  B)  Set  gap  between  ignitor 
electrode and target plate to 
.17" (0.43 cm)
  C) Tighten nut holding piezo 
ignitor to base of heater
  D) Replace ignitor electrode. 
See Ignitor, page 8
1. This can happen when running 
heater in temperatures above 
85°F (29.44° C). Run heater 
in cooler temperatures
2  Check heater inlet and outlet. 
Remove any obstructions
3. Replace fan. See Fan, page 8
4. Clean  heater.  See  Mainte-
nance, page 7 
OBSERVED FAULT
Fan does not turn when heater is 
plugged in
Heater will not ignite
Heater  shuts  down  while  run-
ning
POSSIBLE CAUSE
1. No electrical power to heater
2. Fan  hitting  inside  of  heater 
shell
3. Fan blades bent
4. Defective motor
1. User did not follow installa-
tion or operation instructions 
properly 
2. No spark at ignitor. To test for 
spark, follow step 8 under Ig-
nitor, page 9. If you see spark 
at ignitor, have heater serviced 
by qualified service person. If 
no spark seen:
  A)  Loose  or  disconnected 
ignitor wire
  B) Wrong spark gap
  C) Piezo ignitor loose
  D) Bad ignitor electrode 
1. High  surrounding  air  tem-
perature causing thermal limit 
device to shut down heater
2. Restricted air flow
3. Damaged fan 
4. Excessive  dust  or  debris  in 
surrounding area
 WARNING: Use only in areas 
free of high dust content.