Desa V ユーザーズマニュアル

ページ / 48
107070-01F
For more information, visit www.desatech.com
For more information, visit www.desatech.com
8
INSTALLATION
NOTICE: This heater is intended for use as supple-
mental heat. Use this heater along with your primary
heating system. Do not install this heater as your
primary heat source. If you have a central heating
system, you may run system’s circulating blower
while using heater. This will help circulate the heat
throughout the house. In the event of a power outage,
you can use this heater as your primary heat source.
 WARNING: A qualified service person must in-
stall heater. Follow all local codes.
NOTICE: State or local codes may only allow opera-
tion of this appliance in a vented configuration. Check
your state or local codes.
 WARNING: Make sure the selector switch is in the
OFF position before installing heater (Remote-Ready
Models Only).
 WARNING: Before installing in a solid fuel burn-
ing fireplace, the chimney flue and firebox must be
cleaned of soot, creosote, ashes and loose paint by
a qualified chimney cleaner. Creosote will ignite if
highly heated. A dirty chimney flue and firebox may
create and distribute soot within the house. Inspect
chimney flue for damage. If damaged, repair flue
before operating heater.
 WARNING: Seal any fresh air vents or ash clean-
out doors located on floor or wall of fireplace. If not,
drafting may cause pilot outage or sooting. Use a heat-
resistant sealant. Do not seal chimney flue damper.
 WARNING: Never install the heater
• in a bedroom or bathroom unless installed as a
vented appliance, see page 11 (Remote-Ready and
Variable Manually-Controlled Models Only)
• in a recreational vehicle
• where curtains, furniture, clothing, or other flam-
mable objects are less than 42 inches from the
front, top, or sides of the heater
• in high traffic areas
• in windy or drafty areas
INSTALLATION AND CLEARANCES FOR
VENT-FREE OPERATION
 WARNING: Maintain the minimum clearances. If
you can, provide greater clearances from floor, ceil-
ing, and adjoining wall.
IMPORTANT: 
Vent-free heaters add moisture to the air. Although
this is beneficial, installing heater in rooms without enough venti-
lation air may cause mildew to form from too much moisture. See
Air for Combustion and Ventilation, pages 5 through 7.
CHECK GAS TYPE
Use the correct gas type (natural or propane/LP) for your unit. If
your gas supply is not correct, do not install log set. Call dealer
where you bought log set for proper type fireplace.
 CAUTION: This heater creates warm air currents.
These currents move heat to wall surfaces next to
heater. Installing heater next to vinyl or cloth wall
coverings or operating heater where impurities (such
as, but not limited to, tobacco smoke, aromatic
candles, cleaning fluids, oil or kerosene lamps, etc.)
in the air exist, may discolor walls or cause odors.
INSTALLATION
Check Gas Type
Installation and Clearances for Vent-Free Operation
LOG SIZING REQUIREMENTS
Log
Minimum Firebox
Size
Height Depth Front Rear *
Width Width
18"
17"
14"
24"
20"
24"
17"
14"
28"
21"
30"
17"
14"
34"
24"
36"
17"
14"
40"
30"
MINIMUM FIREPLACE
CLEARANCE TO
COMBUSTIBLE MATERIALS
Log Size
Side Wall
Ceiling
18", 24",
16"
42"
30", and 36"
* Measured at 14" depth.