To Stop Heater
1. Tightly close propane supply valve on propane tank(s). Allow heater to burn
remaining fuel in hose.
2. Shut off main burner valve. Do this by turning valve handle towards the OFF
position until it stops.
To Restart Heater
1. Wait five minutes after stopping heater.
2. Restart heater by following steps under To Start Heater, page 7.
1. Store propane tank(s) in safe manner. Refer to Chapter 5 of Standard for
Storage and Handling of Liquefied Petroleum Gases, ANSI/NFPA 58 and/or
CAN/CGA B149.2. Follow all local codes. Always store propane tanks outdoors.
2. Place plastic cover caps over brass fittings on inlet connector and
hose/regulator assembly.
3. Store in a dry, clean, and safe place.
STORAGE
Figure 6 - Flame Pattern during Flashback
Yellow Flame
Blue Flame
Flame Inside
Burner Tube
(makes roaring noise)
Incorrect Flame
Pattern–Flashback
Burner
Tube
CAUTION
Disconnect heater from propane supply tank(s).
CAUTION
Do not stack heaters over three high if more than one
heater is being stored. Secure heaters with rope or strap
after stacking.