IMPORTANT: Vent-free heaters add moisture 
to the air. Although this is beneficial, installing 
heater  in  rooms  without  enough  ventilation 
air may cause mildew to form from too much 
moisture. See Air for Combustion and Ventila-
tion, 
page 5. If high humidity is experienced, 
a dehumidifier may be used to help lower the 
water vapor content in the air.
For convenience and efficiency, install heater
•  where there is easy access for operation, 
inspection and service
•  in coldest part of room
If planning to use fan, locate heater near an 
electrical outlet.
INSTALLATION
Continued
Figure 5 - Attaching Thermostat Sensing 
Bulb
Clamp
Thermostat 
Sensing 
Bulb
Figure 4 - Mounting Clearances As 
Viewed From Front of Heater
Minimum 
From 
Sides Of 
Heater 
 
2" (5.1 cm) 
FLOOR
CEILING 
36" 
(91.5 cm) 
Minimum 
Minimum To 
Top Surface 
Of Carpeting, 
Tile Or Other 
Combustible 
Material 
 
Left
Side
Right 
Side 
10" (25.4 cm) 
36"
(91.5 cm)
LOCATING HEATER
This heater is designed to be mounted on a wall.
  WARNING:  Maintain  the 
minimum  clearances  shown 
in Figure 4. If you can, provide 
greater  clearances  from  floor, 
ceiling and joining wall.
You can locate heater on floor, away from a 
wall. An optional floor mounting stand is need-
ed. Purchase the floor mounting stand from 
your dealer. See Accessories, page 21.
 WARNING: Never install the 
heater
•  in a bedroom or bathroom
•  in a recreational vehicle
•  where  curtains,  furniture, 
clothing or other flammable 
objects  are  less  than  36" 
(91.5 cm) from the front, top 
or sides of the heater
•  as a fireplace insert
•  in high traffic areas
•  in windy or drafty areas
 CAUTION: If you install the 
heater in a home garage
•  heater  pilot  and  burner  must 
be at least 18" (45.7 cm) above 
floor
•  locate  heater  where  moving 
vehicle will not hit it
 CAUTION: This heater creates 
warm air currents. These currents 
move heat to wall surfaces next 
to  heater.  Installing  heater  next 
to vinyl or cloth wall coverings or 
operating heater where impurities 
(such  as,  but  not  limited  to,  to-
bacco smoke, aromatic candles, 
cleaning  fluids,  oil  or  kerosene 
lamps, etc.) in the air exist, may 
discolor walls or cause odors.
THERMOSTAT SENSING BULB
The thermostat sensing bulb has been placed 
below the heater.
1.  Place clamp on thermostat sensing bulb 
as shown in Figure 5. Clamp is provided 
in hardware package.
2.  Snap clamp into upper mounting hole as 
shown in Figure 5. Mounting hole is located 
on lower left edge on back of heater. Make 
sure the thermostat sensing bulb is point-
ing up.