OPERATION
Continued
MANUAL CONTROL INFRARED 
MODELS ONLY
TO SELECT 
HEATING LEVEL
  WARNING:  When  running 
heater, set control knob at LOW 
or  HIGH  locked  positions  for 
double burner heater or ON po-
sition for single burner heater. 
Never set control knob between 
locked positions. Poor combus-
tion and higher levels of carbon 
monoxide may result.
 CAUTION: Do not try to ad-
just heating levels by using the 
equipment shutoff valve.
  Control   Double
  Knobs  Burners
ON
OFF
PILOT
IGN
OFF
  Control   Single
  Knob  Burner
Figure 20 - Burner Patterns
INSPECTING BURNER
Thermocouple
Pilot Burner
Pilot Burner
Thermocouple
Figure 21 - Correct Pilot Flame Pattern
Figure 22 - Incorrect Pilot Flame Pattern
Slightly press in control knob and turn counter-
clockwise 
 to the LOW or HIGH positions 
for double burner heater or ON position for 
single burner heater.
IMPORTANT:  Release  downward  pressure 
while turning control knob. Control knob will 
lock at the desired position.
Check  pilot  flame  pattern  and  burner flame 
pattern often.
PILOT FLAME PATTERN
Figure 21 shows a correct pilot flame pattern. 
Figure 22 shows an incorrect pilot flame pat-
tern. The incorrect pilot flame is not touching 
the thermocouple. This will cause the thermo-
couple to cool. When the thermocouple cools, 
the heater will shut down.
If  pilot  flame  pattern  is  incorrect,  as  shown 
in Figure 22
•  turn heater off (see To Turn Off Gas to Ap-
pliance, page 14)
•  see Cleaning, page 17
Note: The pilot flame on natural gas units will 
have a slight curve, but flame should be blue 
and have no yellow or orange color.