Desa HDR16PT ユーザーズマニュアル

ページ / 56
www.desatech.com
13
121255-01A
4.  Check all joints of gas supply piping system. 
Apply a noncorrosive leak detection fluid to 
all joints. Bubbles forming show a leak.
5.  Correct all leaks at once.
6.  Reconnect heater and equipment shutoff 
valve to gas supply. Check reconnected 
fittings for leaks.
Test Pressures Equal To or Less Than 
1/2 PSIG (3.5 kPa)
1.  Close equipment shutoff valve (see Fig-
ure 16).
2.  Pressurize supply piping system by either 
opening  propane/LP  supply  tank  valve 
for propane/LP gas or opening main gas 
valve  located  on  or  near  gas  meter  for 
natural gas or using compressed air.
3.  Check all joints from gas meter for natural 
gas (see Figure 17) or propane/LP supply 
tank  for  propane/LP  gas,  to  equipment 
shutoff  valve  (see  Figure  18). Apply  a 
noncorrosive  leak  detection  fluid  to  all 
joints. Bubbles forming show a leak.
4.  Correct all leaks at once.
PRESSURE TESTING HEATER GAS 
CONNECTIONS
1.  Open equipment shutoff valve (see Fig-
ure 16).
2.  For  natural  gas  open  main  gas  valve 
located  on  or  near  gas  meter.  For  pro-
pane/LP  gas  open  propane/LP  supply 
tank valve.
3.  Make sure control knob of heater is in the 
OFF position.
4.  Check  all  joints  from  equipment  shutoff 
valve to thermostat gas valve (see Figure 
17 or 18). Apply a noncorrosive leak de-
tection fluid to all joints. Bubbles forming 
show a leak.
5.  Correct all leaks at once.
6.  Light  heater  (see  Operation).  Check  all 
other internal joints for leaks.
7.  Turn off heater (see To Turn Off Gas to 
Appliance, page 15).
8.  Replace front panel.
Figure 18 - Checking Gas Joints for 
Propane/LP Gas
Figure 16 - Equipment Shutoff Valve
Equipment 
Shutoff 
Valve
Propane/LP 
Supply Tank
Thermostat Gas Valve
Open
Closed
Equipment 
Shutoff Valve
Figure 17 - Checking Gas Joints for 
Natural Gas
Equipment 
Shutoff 
Valve
Gas 
Meter
Thermostat Gas Valve
INSTALLATION
Continued
OPERATION
FOR YOUR SAFETY READ 
BEFORE LIGHTING
 WARNING: If you do not fol-
low  these  instructions  exactly, 
a  fire  or  explosion  may  result 
causing property damage, per-
sonal injury or loss of life.
A.  This appliance has a pilot which must 
be  lighted  by  hand.  When  lighting 
the  pilot,  follow  these  instructions 
exactly.
B.  BEFORE  LIGHTING  smell  all  around 
the appliance area for gas. Be sure to 
smell next to the floor because some 
gas is heavier than air and will settle 
on the floor.