ventilation Air From Outdoors
Provide  extra  fresh  air  by  using  ventilation 
grills or ducts. You must provide two perma-
nent  openings:  one  within  12"  (30.5  cm)  of 
the  ceiling  and  one  within  12"  (30.5  cm)  of 
the floor. Connect these items directly to the 
outdoors  or  spaces  open  to  the  outdoors. 
These  spaces  include  attics  and  crawl 
spaces. Follow the National Fuel Gas Code, 
ANSI  Z223.1/NFPA  54,  Section  5.3, Air  for 
Combustion and Ventilation
 for required size 
of ventilation grills or ducts.
IMPORTANT:  Do  not  provide  openings  for 
inlet or outlet air into attic if attic has a thermo-
stat-controlled power vent. Heated air entering 
the attic will activate the power vent.
AIR FOR COMbUSTION 
AND VENTILATION
Continued
Figure 2 - Ventilation Air from Inside 
Building
Figure 3 - Ventilation Air from Outdoors
INSTALLATION
NOTICE:  This  heater  is  intended 
for use as supplemental heat. Use 
this heater along with your primary 
heating system. Do not install this 
heater as your primary heat source. 
If you have a central heating system, 
you may run system’s circulating 
blower while using heater. This will 
help circulate the heat throughout 
the house. In the event of a power 
outage, you can use this heater as 
your primary heat source.
  WARNING: A  qualified  ser-
vice person must install heater. 
Follow all local codes.
CHECK GAS TYPE
Use only the correct type of gas (natural or 
propane/LP).  If  your  gas  supply  is  not  the 
correct  gas  type,  do  not  install  heater.  Call 
dealer  where  you  bought  heater  for  proper 
type heater.
 WARNING: This appliance is 
equipped for either natural gas 
or propane/LP gas but not both. 
Gas type is indicated on the rat-
ing plate. Field conversion is not 
permitted.
INSTALLATION ITEMS
Before installing heater, make sure you have 
the items listed below.
•  for  propane/LP  gas,  external  regulator 
(supplied by installer)
•  piping (check local codes)
•  sealant (resistant to propane/LP gas)
•  equipment shutoff valve *
•  ground joint union
•  sediment trap
•  tee joint
•  pipe wrench
•  for natural gas, test gauge connection*
*  A CSA design-certified equipment shutoff 
valve with 1/8" NPT tap is an acceptable alter-
native to test gauge connection. The optional 
CSA design-certified equipment shutoff valve 
can be purchased from your dealer. See Ac-
cessories
, page 21.
Or  
Remove  
Door into  
Adjoining  
Room,  
Option 3 
Ventilation Grills  
Into Adjoining Room, 
Option 2 
12" 
12" 
Ventilation
Grills into
Adjoining
Room, 
Option 1
Outlet
Air
Ventilated
Attic 
Outlet
Air
Inlet
Air
Inlet Air
Ventilated 
Crawl Space
To 
Crawl
Space
To Attic