Desa RCLP100V ユーザーズマニュアル

ページ / 28
www.desatech.com
103908-01E
12
SPECIFICATIONS
At LOW setting
•  Output Rating - 65,000 Btu/Hr (61,000 kJ/Hr)
•  Fuel Consumption - 0.7 Gal/Hr (2.6 Litres/Hr)
•  Fuel Consumption - 3.0 lb/Hr (1.36 kg/Hr)
At MED setting
•  Output Rating - 85,000 Btu/Hr (80,570 kJ/Hr)
•  Fuel Consumption - 0.93 Gal/Hr (3.5 Litres/Hr)
•  Fuel Consumption - 3.9 lb/Hr (1.8 kg/Hr)
At HIGH setting
•  Output Rating - 100,000 Btu/Hr (94,800 kJ/Hr)
•  Fuel Consumption - 1.1 Gal/Hr (4.2 Litres/Hr)
•  Fuel Consumption - 4.6 lb/Hr (2.1 kg/Hr)
For all settings
•  Propane Vapor Fuel Only
•  Supply Pressure To Regulator:
  Minimum (for purposes of input adjustment) 
10 psi (69 kPa)
  Maximum - Tank Pressure
•  Regulator Outlet Pressure - Factory Preset
•  Manifold Pressure - 10" (25.4 cm) WC
•  Hot Air Output (CFM Approx) - 475 (13.45 m)
•  Motor - 3,200 RPM, 1/10 HP
•  Electric Input - 120 V/60 Hz
•  Amperage - 2.9
•  Ignition - Continuous
•  Ignitor Gap - 0.13"/0.15" (3.3/3.8 mm)
TECHNICAL SERVICE
You may have further questions about this heater. 
If so, contact DESA Heating Productsʼ Technical 
Service  Department  at  1-866-672-6040. When 
calling, please have your model and serial numbers 
of your heater ready.
You can also visit DESA Heating Productsʼ Techni-
cal Service web site at www.desatech.com.
REPLACEMENT PARTS
 WARNING: Use only original 
replacement parts. This heater 
must use design-specific parts. 
Do not substitute or use generic 
parts.  Improper  replacement 
parts could cause serious or fa-
tal injuries. This will also protect 
your warranty coverage for parts 
replaced under warranty.
PARTS UNDER WARRANTY
Contact authorized dealers of this product. If they 
canʼt  supply  original  replacement  part(s),  call 
DESA Industries at 1-905-826-8010.
When calling DESA Industries, have ready
•  your name
•  your address
•  model number of your heater
•  how heater was malfunctioning
•  purchase date
In most cases, we will ask you to return the part 
to the factory.
PARTS NOT UNDER WARRANTY
Contact authorized dealers of this product. If 
they canʼt supply original replacement part(s), 
call  DESA  Industriesʼ  Parts  Department  at 
1-905-826-8010.
When calling DESA Industries, have ready:
•  model number of your heater
•  the replacement part number
ACCESSORY
Purchase accessories and parts from your nearest 
dealer or service center. If your dealer or service 
center can not supply an accessory or part, call DESA 
Industriesʼ Parts Department at 1-905-826-8010. You 
can also write to the address listed on the back page 
of this manual.
FUEL GAS CONNECTOR - LPA4020
Connects regulator to all standard propane tanks. 
U.L. and A.G.A. listed.