REMEDY
1. Check  voltage  to  electrical 
outlet. If voltage is good, check 
heater power cord for breaks
2. Adjust  motor/fan  mount  to 
keep fan from hitting inside of 
heater shell. Bend fan mount 
if necessary
3. Replace fan. See Fan, page 7
4. Replace  motor.  See  Motor
page 6
1. Repeat installation and operation 
instructions. See Installation
page 4 and Operation, page 5
2. A) Check ignitor wire. Tighten 
or reattach loose ignitor wire. 
See  Figure  10,  page  8  for 
ignitor wire location
  B) Assure gap between ignitor 
electrode and target plate is 
0.13"/0.15" (3.3/3.8 mm). Do 
not bend electrode. Doing so 
may cause it to break
  C) Replace ignitor electrode. 
See Ignitor, page 8
  D) Replace spark transformer. 
See Spark Transformer, page 8
1. A) Refill tank
  B) Provide additional and/or 
larger  tanks.  See  Propane 
Supply, page 3
2. This can happen when running 
heater in temperatures above 
85°F  (29˚C).  Run  heater  in 
cooler temperatures
3. Check heater inlet and outlet. 
Remove any obstructions
4. Replace fan. See Fan, page 7
5. Clean  heater.  See  Mainte-
nance, page 6
POSSIBLE CAUSE
1. No electrical power to heater
2.  Fan  hitting  inside  of  heater 
shell
3. Fan blades bent
4. Defective motor
1. User did not follow installa-
tion or operation instructions 
properly
2. No spark at ignitor. To test for 
spark, follow step 8 under Ig-
nitor, page 8. If you see spark 
at ignitor, have heater serviced 
by qualified service person. If 
no spark seen:
  A)  Loose  or  disconnected 
ignitor wire
  B) Wrong spark gap
  C) Bad ignitor electrode
  D) Bad spark transformer
1. Propane supply may be inad-
equate
2. High  surrounding  air  tem-
perature causing thermal limit 
device to shut down heater.
3. Restricted air flow
4. Damaged fan 
5. Excessive  dust  or  debris  in 
surrounding area
OBSERVED FAULT
Fan does not turn when heater is 
plugged in
Heater will not ignite
Heater  shuts  down  while  run-
ning
TROUBLESHOOTING
 
 WARNING: Never service heater while it is plugged in, connected 
to propane supply, operating, or hot. Severe burns and electrical 
shock can occur.
 WARNING: Use only in areas 
free of high dust content.