Desa 30-80 ユーザーズマニュアル

ページ / 32
www.desatech.com
113811-01A
4
200,000
 
BTU/HR
INSTALLATION
 WARNING: Review and un-
derstand  the  warnings  in  the 
Safety Information section, page 
2. They are needed to safely op-
erate this heater. Follow all local 
codes when using this heater.
 CAUTION: Never ignite and/
or  run  this  heater  uhnless  the 
shells  are  fully  extended  and 
locked into position.
OUTER SHELL
IMPORTANT:
 When the heater is first removed 
from carton, the outer shell is in the down posi-
tion. Protect hands before lifting outer shell. Never 
grasp bare metal without hand protection.
CONNECTING TO GAS SUPPLY
 WARNING: Test all gas piping 
and connections for leaks after 
installation or servicing. Never 
use an open flame to check for 
a leak. Apply a mixture of liquid 
soap  and  water  to  all  joints. 
Bubbles  forming  show  a  leak. 
Correct all leaks at once. 
1.  Provide propane supply system (see Propane 
Supply, 
page 4).
2.  Connect fuel gas fitting on hose/regulator 
assembly  to  propane  tank(s).  Turn  fuel 
gas  fitting  counterclockwise  into  threads 
on  tank.  Tighten  firmly  using  a  wrench. 
IMPORTANT: 
Tighten regulator with vent 
pointing down. Pointing vent down protects 
regulator from weather damage.
3.  Connect hose to the valve inlet. Tighten firmly 
using a wrench. You must use the regulator sup-
plied with heater even if propane tank has one.
Figure 2 - Lifting Outer Shell
3 Screws 
per Clip
Outer 
Shell
Clip in Slot 
of Lower 
Shell
PROPANE SUPPLY
You  must  provide  propane  gas  and  propane 
tank(s).
Use  this  heater  only  with  a  propane  vapor 
withdrawal supply system. See Chapter 5 of the 
Standard for Storage and Handling of Liquefied 
Petroleum Gas, ANSI/NFPA 58 and/or CAN/CGA 
B149.2. Your local library or fire department will 
have this booklet.
This heater will operate with a 20-pound (9,07 kg) 
propane tank. However, you can only operate it in 
the LOW position during mildly cool weather. At 
higher heat settings or during colder weather, you 
must use larger tanks.
The amount of propane gas ready for use from 
propane  tanks  varies. Two  factors  decide  this 
amount.
1.  The amount of propane gas in tank(s)
2.  The temperature of tank(s)
The chart below shows the minimum number of 
100-pound (45 kg) tanks needed to run the heater. 
Connect tanks together with a manifold. 
 Average Temperature °F(°C) 
Number
 
At Tank Location 
Of Tanks
 
(80,000 Btu models) 
  20° (-6.7°) to 60° (15,6°) 
1
  0° (-17,8°) to 20° (-6.7°) 
2
 
(200,000 Btu models) 
  20° (-6.7°) to 60° (15,6°) 
2
  0° (-17,8°) to 20° (-6.7°) 
3
Less gas is vaporized at lower temperatures. Your 
local propane gas dealer will help you select the 
proper supply system.
1.  Care must be taken to protect hands during this 
step. Lift outer shell straight up as shown in Fig-
ure 2, until all three clips engage slots in lower 
shell. Screw holes will line up at this point.
2.  Lock clips into place with 3 screws as shown 
in Figure 2. The heater must not be operated 
unless the outer shell is properlly extended 
and fully locked into place.