INSTALLING DAMPER CLAMP ACCESSORY 
FOR VENTED OPERATION
Note: When used as a vented decorative, ap pli ance must be installed 
only in a solid-fuel burning fi replace with a working fl ue and con-
structed of noncombustible material.
If your heater is a non-thermostatically-controlled mod el, you may 
use this heater as a vented prod uct. There are three reasons for op er -
at ing your heater in the vented mode. 
1. The 
fi replace does not meet the clear ance to com bus ti bles 
re quire ments  for  vent-free  operation. 
2.  State or local codes do not permit vent-free operation. 
3.  You prefer vented operation. 
If reasons number 1 or 2 above apply to you, you must permanently 
open chim ney fl ue damper. You must install the damper clamp ac-
cessory (to order, see Accessories, page 27). This will insure vented 
op er a tion (see Figure 10). The damper clamp will keep damper open. 
Installation instructions are included with clamp accessory. 
See chart below for minimum permanent fl ue opening you must 
provide. Attach damp er clamp so the minimum permanent fl ue 
opening will be main tained at all times. 
Area of Various Standard
Round Flues
  Diameter (ins.) 
Area (sq. ins.)
 
5" 
20 sq. inches
 
6" 
29 sq. inches
 
7" 
39 sq. inches
 
8" 
51 sq. inches
  Chimney   Minimum Permanent 
  Height (ft.)  Flue Opening (sq. ins.)
 
6' to 15' 
39 sq. inches
  15' to 30' 
29 sq. inches
INSTALLATION
Continued 
INSTALLING HEATER ASSEMBLY
  WARNING: If installing in a sunken fi re place, 
special care is needed. You must raise the fi re place 
fl oor to allow access to heat er control panel. This will 
in sure ad e quate air fl ow and guard against soot ing. 
Raise fi replace  fl oor with noncom bus ti ble ma te ri al. 
Make sure material is secure.
  CAUTION: Do not pick up heat 
er as 
sem bly by 
logs. This could damage unit. Only handle  assembly 
by grates.
IMPORTANT: Make sure the heater burn ers are level. If heater is 
not level, heater will not work properly.
Installation Items Needed
•  control cover kit (provided with heater)
• approved fl exible gas hose and fi ttings  (pro vid ed  with  heater)  
(if al lowed by lo cal codes) 
•  sealant (resistant to propane/LP gas, not pro vid ed)
Note: Install optional GHRCTA Receiver and Hand-Held Remote 
Control Kit (see Ac ces so ries, page 27) before in stall ing  gas  log 
heater (Remote-Ready Models Only). See installation in struc tions 
in clud ed  with  the  kit. 
1.  Apply pipe joint sealant lightly to male threads of gas fi tting 
(not provided). Connect ap proved fl exible gas hose to inlet side 
of gas con trol (see Figure 11).
2.  Position heater assembly in fi re place. 
3.  Connect to gas supply. See Con nect ing  To  Gas  Supply, (see 
Figure 12, page 11).
INSTALLATION
Installing Damper Clamp Accessory for Vented Operation
Installing Heater Assembly
Figure 11 - Attaching Flexible Gas Hose to Heater Gas 
Regulator 
Gas Control 
Flexible Gas 
Hose (if allowed 
by local codes) 
Figure 10 - Attaching Damper Clamp
Damper
Damper Clamp
Damper
Manufactured Fire place
Masonry Fire place
Damper Clamp
Damper