Desa RG30P ユーザーズマニュアル

ページ / 32
www.desatech.com
114683-01B
21
OBSERVED PROBLEM
ODS/pilot lights but flame goes 
out  when  control  knob  is  re-
leased
Burner does not light after ODS/
pilot is lit
Delayed ignition of burner
Burner  backfiring  during  com-
bustion
REMEDY
1. Press in control knob fully
2. After ODS/pilot lights, keep con-
trol knob pressed in 30 seconds
3. Wait one minute for safety in-
terlock system to reset. Repeat 
ignition operation
4. Fully open equipment shutoff 
valve
5. Hand tighten until snug, then 
tighten 1/4 turn more
6. A)  Contact  local  natural  or 
propane/LP gas company
  B)  Clean  ODS/pilot  (see 
Cleaning  and  Maintenance
page 19) or replace ODS/pilot 
assembly 
7. Replace pilot assembly
8. Replace control valve
1. Clean  burner  (see  Cleaning 
and  Maintenance,  page  19) 
or replace burner orifice
2. Contact local natural or pro-
pane/LP gas company
1. Contact local natural or pro-
pane/LP gas company
2. Clean  burner  (see  Cleaning 
and  Maintenance,  page  19) 
or replace burner orifice
1. Clean  burner  (see  Cleaning 
and  Maintenance,  page  19) 
or replace burner orifice
2. Replace burner
3. Replace gas regulator
POSSIBLE CAUSE
1. Control knob not fully pressed in
2. Control knob not pressed in 
long enough
3. Safety  interlock  system  has 
been triggered 
4. Equipment shutoff valve not 
fully open
5. Thermocouple  connection 
loose at control valve 
6. Pilot flame not touching ther-
mocouple, which allows ther-
mocouple  to  cool,  causing 
pilot  flame  to  go  out. This 
problem could be caused by 
one or both of the following:
  A) Low gas pressure
  B) Dirty or partially clogged 
ODS/pilot 
7. Thermocouple damaged
8. Control valve damaged
1. Burner orifice is clogged
2. Inlet gas pressure is too low
1. Manifold pressure is too low
2. Burner orifice is clogged
1. Burner orifice is clogged or 
damaged
2. Burner damaged
3. Gas regulator defective
TROUBLESHOOTING
Continued