Desa CGN18R ユーザーズマニュアル

ページ / 32
18
099434
4. Wait five (5) minutes to clear out any gas. Then smell for gas, including
near the floor. If you smell gas, STOP! Follow “B” in the safety information
at the top of page 17. If you don’t smell gas, go to the next step.
5. Press in control knob.
Note:
 
You may be running this heater for the first time after hooking up
to gas supply. If so, you may need to press in control knob for 30 seconds.
This will allow air to bleed from the gas system.
• If control knob does not pop up when released, contact a qualified
service person or gas supplier for repairs.
6. Keep control knob pressed in and turn it counterclockwise 
C-clockwise
 to the
PILOT/IGN position. This will light pilot.
Note:
 You will hear a loud “click” when the control knob reaches the
PILOT/IGN position.
If pilot does not light
• turn control knob clockwise 
Clockwise
 to the OFF position
• repeat steps 5 and 6
If pilot does not stay lit after several tries
• refer to Troubleshooting, pages 22 through 25
• contact a qualified service person or gas supplier for repairs
Until repairs are made, light pilot with match. To light pilot with match, see
Manual Lighting Procedure
, page 20.
7. Keep control knob pressed in for 10 seconds after lighting pilot. After 10
seconds, release control knob.
Note:
 If pilot goes out, repeat steps 3 through 7.
Ignitor Electrode
Figure 16 - Pilot
Pilot Burner
Thermocouple
OPERATING
HEATER
Continued