Desa BVDR18 ユーザーズマニュアル

ページ / 28
www.desatech.com
901746-01E
8
INSTALLATION
Continued
CHECkING GAS CONNECTIONS
 WARNING: Test all gas piping 
and  connections,  internal  and 
external to unit, for leaks after 
installing or servicing. Correct 
all leaks at once.
  WARNING:  Never  use  an 
open flame to check for a leak. 
Apply a noncorrosive leak detec-
tion fluid to all joints. Bubbles 
forming show a leak. Correct all 
leaks at once.
PRESSURE TESTING GAS SUPPLY 
PIPING SYSTEM 
Test Pressures In Excess Of 1/2 PSIG 
(3.5 kPa)
1.  Disconnect log set and its individual equip-
ment shutoff valve from gas supply piping 
system.
2.  Cap off open end of gas pipe where equip-
ment shutoff valve was connected.
3.  Pressurize supply piping system by either 
using compressed air or opening main gas 
valve located on or near gas meter.
4.  Check all joints of gas supply piping sys-
tem. Apply a noncorrosive leak detection 
fluid to all joints. Bubbles forming show a 
leak.
5.  Correct all leaks at once.
6.  Reconnect log set and equipment shutoff 
valve to gas supply. Check reconnected 
fittings for leaks.
Test Pressures Equal To or Less Than 
1/2 PSIG (3.5 kPa)
1.  Close  equipment  shutoff  valve  (see 
Figure 5).
2.  Pressurize supply piping system by either 
using compressed air or opening main gas 
valve located on or near gas meter.
3.  Check all joints from gas meter to equip-
ment shutoff valve (see Figure 6). Apply 
a noncorrosive leak detection fluid to all 
joints. Bubbles forming show a leak. 
4.  Correct all leaks at once.
Figure 6 - Checking Gas Joints
Gas Meter
Equipment 
Shutoff Valve
HEARTH KIT ASSEMBLy AND 
INSTALLATION
Kit Assembly
Note:  The  following  instructions  apply  to 
both standard single bar burners, as well as 
dual flame “U” style burners. Be sure all pipe 
threaded  connections  are  tight,  and  have 
thread compound to prevent leaks.
1.  Determine which side the gas line will be 
coming into the fireplace.
2.  Using a hammer and screw driver, remove 
knock-out plug from the side of the pan 
that  corresponds  to  the  gas  line  (see 
Figure 7).
3.  Unscrew  burner  inlet  fitting  from  burner 
manifold (see Figure 8, page 9).
4.  Place burner manifold in pan with thread-
ed opening facing open knock-out plug. 
Figure 5 - Equipment Shutoff Valve
Open
Closed
Equipment 
Shutoff 
Valve
Knock-out 
Plugs
Figure 7 - Knock-Out Plug Locations