Desa BVSR18 ユーザーズマニュアル

ページ / 28
www.desatech.com
901746-01E
15
INSPECTING BURNERS 
Thermocouple
Figure 23 - Correct Pilot Flame Pattern
Pilot
Check  pilot  flame  pattern  and  burner flame 
patterns often.
PILOT ASSEMBLy
The pilot assembly is factory preset for proper 
flame height. Alterations may have occurred 
during  shipping  and  handling.  The  pilot  is 
located on back right hand side of burner.
The thermocouple should be fully enveloped 
in flame. Flame should not be lifting off ther-
mocouple element.
If  your  pilot  assembly  does  not  meet  these 
requirements:
•  Access  pilot  adjustment  screw  through 
slot in valve cover. Turn adjustment screw 
clockwise to decrease or counterclockwise 
to increase flame to proper size (see Figure 
17, page 11). Do not remove adjustment 
screw.
•  see Troubleshooting, page 16
BURNER FLAME PATTERN
Burner  flames  will  be  steady;  not  lifting  or 
floating.  Flames  should  go  up  through  the 
middle of log set. Flames should not "spill" to 
edges of pan or sides of log set.
Figure  24  shows  a  typical  flame  pattern.  If 
burner  flame  pattern  differs  from  that  de-
scribed:
•  turn appliance off (see To Turn Off Gas to 
Appliance, page 14) 
•  see Troubleshooting, page 16
Figure 24 - Typical Flame Pattern
CLEANING AND MAINTENANCE
•  Keep area around log set clean and clear 
of debris.
•  Occasionally,  you  may  use  a  soft  bristle 
brush to clean logs.
•  Periodically  inspect  air  mixer  and  burner 
tube  for  foreign  matter  blocking  air  inlet 
and flame holes.
•  Once  every  year  a  qualified  agency  or 
certified  chimney  sweep  should  examine 
and clean venting system of fireplace.