FIREPLACE INSTALLATION
Continued
IMPORTANT:.Install.main.gas.valve.(equip-
ment.shutoff.valve).in.an.accessible.location..
The.main.gas.valve.is.for.turning.on.or.shutting.
off.gas.to.appliance.
Check. your. building. codes. for. any. special.
requirements.for.locating.equipment.shutoff.
valve to fireplaces.
Apply pipe joint sealant lightly to male NPT 
threads..This.will.prevent.excess.sealant.from.
going.into.pipe..Excess.sealant.in.pipe.could.
result in clogged fireplace valves.
  WARNING:  Use  pipe  joint 
sealant that is resistant to liquid 
petroleum (LP) gas.
We. recommend. that. you. install. a. sediment.
trap/drip.leg.in.supply.line.as.shown.in.Figure.
23,  page  15.  Locate  sediment  trap/drip  leg 
where. it. is. within. reach. for. cleaning.. Install.
in. piping. system. between. fuel. supply. and.
fireplace. Locate sediment trap/drip leg where 
trapped matter is not likely to freeze. A sedi-
ment.trap.traps.moisture.and.contaminants..
This  keeps  them  from  going  into  fireplace 
gas.controls..If.sediment.trap/drip.leg.is.not.
installed or is installed wrong, fireplace may 
not.run.properly.
CONNECTING FIREPLACE TO GAS 
SUPPLY
Installation Items Needed
•  3/4" and a 7/8" open end wrench or adjust-
able.wrench
•  sealant (resistant to propane/LP gas, not 
provided)
1.. Remove.lower.louver.door.panel.by.lifting.
up.until.disengaged..Swing.forward.and.
out.of.locating.slots.at.bottom.
2.  Route  flexible  gas  line  (provided  by  in-
staller). from. equipment. shutoff. valve. to.
fireplace.  Route  flexible  gas  supply  line 
through.one.access.hole.on.each.side.of.
fireplace cabinet.
3.  Attach flexible gas line from gas supply 
to the 1/2" flare fitting provided on control 
valve.(see.Figure.4).
4.. Check.all.gas.connections.for.leaks.(see.
Checking Gas Connections).
Figure 24 - Connecting Flexible Gas Line 
to Millivolt Valve
Flexible.Gas.Line.
Do.NOT.Kink
Equipment.
Shutoff.Valve
To.Gas.Supply.
(Natural)
To.External.
Regulator.
(Propane/LP)
Control.Valve
CHECKING GAS CONNECTIONS
 WARNING: Test all gas piping 
and  connections,  internal  and 
external to unit, for leaks after 
installing or servicing. Correct 
all leaks at once.
 WARNING: Never use an open 
flame to check for a leak. Apply 
noncorrosive leak detection fluid 
to all joints. Bubbles forming show 
a leak. Correct all leaks at once.
PRESSURE TESTING GAS SUPPLY 
PIPING SYSTEM
Test Pressures In Excess Of 1/2 PSIG 
(3.5 kPa)
1.  Disconnect  fireplace  and  its  individual 
equipment.shutoff.valve.from.gas.supply.
piping.system..Pressures.in.excess.of.1/.
psig (3.5 kPa) will damage fireplace gas 
regulator.
.. Cap.off.open.end.of.gas.pipe.where.equip-
ment.shutoff.valve.was.connected.
3.  Pressurize supply piping system by either 
opening. propane/LP. supply. tank. valve.
for propane/LP gas fireplace or opening 
main.gas.valve.located.on.or.near.gas.
meter for natural gas fireplace or using 
compressed.air.
4.  Check all joints of gas supply piping sys-
tem..Apply. noncorrosive. leak. detection.
fluid to all joints. Bubbles forming show a 
leak..Correct.all.leaks.at.once.
5.. Reconnect. fireplace. and. equipment.
shutoff.valve.to.gas.supply..Check.recon-
nected fittings for leaks.