Desa FG30NT ユーザーズマニュアル

ページ / 32
www.desatech.com
114683-01B
17
Figure 22 - Pilot (actual pilot may vary)
6.  With control knob pressed in, push down 
and release ignitor button. This will light 
pilot. The pilot is attached to the front of 
burner. The pilot is attached to the front of 
the burner. If needed, keep pressing ignitor 
button until pilot lights.
 
Note:
 If pilot does not stay lit, refer to 
Troubleshooting, page 20. Also contact a 
qualified service person or gas supplier for 
repairs. Until repairs are made, light pilot 
with match. To light pilot with match, see 
Manual Lighting Procedure.
7.  Keep control knob pressed in for 30 seconds 
after lighting pilot. After 30 seconds, release 
control knob.
• If control knob does not pop up when 
released, contact a qualified service person 
or gas supplier for repairs.
  Note:  If  pilot  goes  out,  repeat  steps  3 
through 7. This heater has a safety inter-
lock system. Wait one (1) minute before 
lighting pilot again.
8.  Turn control knob counterclockwise 
 
to desired heating level. The main burner 
should light. Set control knob to any heat 
level between 1 and 5.
 CAUTION: Do not try to ad-
just heating levels by using the 
equipment shutoff valve.
OPERATING HEATER
Continued
Ignitor Electrode
Pilot Burner
Thermocouple
TO TURN OFF GAS 
TO APPLIANCE
Shutting Off Heater
1.  Turn control knob clockwise 
 to the 
OFF position.
2.  Turn off all electric power to the appliance 
if service is to be performed.
Shutting Off Burner Only (pilot stays lit)
Turn  control  knob  clockwise 
    to  the 
PILOT position.
THERMOSTAT CONTROL 
OPERATION
The thermostatic control used on these models 
differs from standard thermostats. Standard 
thermostats simply turn on and off the burner. 
The thermostat used on this heater senses the 
room temperature. The thermostat adjusts the 
amount of gas flow to the burner. This increases 
or decreases the burner flame height. At times 
the room may exceed the set temperature. If so, 
the burner will shut off. The burner will cycle 
back on when room temperature drops below the 
set temperature. The control knob can be set to 
any heat level between 1 and 5. Selecting the 5 
setting will cause the burner to remain fully on 
without modulating down in most cases.
Note:
 The thermostat sensing bulb measures 
the temperature of air near the heater cabinet. 
This may not always agree with room tem-
perature (depending on housing construction, 
installation location, room size, open air tem-
peratures, etc.). Frequent use of your heater will 
let you determine your own comfort levels.
MANUAL LIGHTING 
PROCEDURE
1.  Remove front panel (see Figure 7, page 9).
2.  Follow steps 1 through 5 under Lighting 
Instructions
, page 16.
3.  With control knob pressed in, strike match. 
Hold match to pilot until pilot lights. 
4.  Keep control knob pressed in for 30 seconds 
after lighting pilot. After 30 seconds, release 
control  knob.  Now  follow  step  8,  under 
Lighting Instructions
, column 1.
5.  Replace front panel.