INSTALLATION
Continued
CONNECTING TO GAS SUPPLY
 WARNING: A qualified ser-
vice  person  must  connect  log 
set  to  gas  supply.  Follow  all 
local codes.
Installation Items Needed
Before installing log set, make sure you have 
the items listed below.
•  piping (check local codes)
•  sealant (resistant to propane/LP gas)
•  equipment shutoff valve
•  test gauge connection
•  adjustable (crescent) wrench or pliers
•  sediment trap
•  tee joint
•  pipe wrench
  CAUTION:  Use  only  new, 
black  iron  or  steel  pipe.  Inter-
nally-tinned copper tubing may 
be used in certain areas. Check 
your  local  codes.  Use  pipe  of 
1/2" diameter or greater to allow 
proper gas volume to log set. If 
pipe is too small, undue loss of 
volume will occur.
Installation must include an equipment shutoff 
valve,  union,  and  a  plugged  1/8"  NPT  tap. 
Locate NPT tap within reach for test gauge 
hook up. NPT tap must be upstream from log 
set (see Figure 4).
IMPORTANT: Install equipment shutoff valve 
in  an  accessible  location.  The  equipment 
shutoff valve is for turning on or shutting off 
gas to appliance.
Apply pipe joint sealant lightly to male NPT 
threads. This will prevent excess sealant from 
going into pipe. Excess sealant in pipe could 
result in a clogged burner injector.
  WARNING:  Use  pipe  joint 
sealant that is resistant to liquid 
petroleum (LP) gas. 
We  recommend  that  you  install  a  sediment 
trap in the supply line as shown in Figure 4. 
Locate sediment trap where it is within reach 
for cleaning. Install in piping system between 
fuel  supply  and  heater.  Locate  sediment 
trap  where  trapped  matter  is  not  likely  to 
freeze. A  sediment  trap  traps  moisture  and 
contaminants.  This  keeps  them  from  going 
into log set controls. If sediment trap is not 
installed  or  is  installed  wrong,  log  set  may 
not run properly.
Figure 4 - Gas Connection
* Purchase the optional CSA design-certified 
equipment shutoff valve from your dealer.
** Minimum inlet pressure for purpose of input 
adjustment.
3" Minimum
From Gas 
Meter (5" 
W.C.** to 
10.5" W.C. 
Pressure)
CSA Design-Certified 
Equipment Shutoff Valve 
With 1/8" NPT Tap*
Approved Flexible 
Gas Hose (if allowed 
by local codes)
Tee  Pipe  Cap
Joint  Nipple
Sediment Trap