Desa CRN30 ユーザーズマニュアル

ページ / 32
www.desatech.com
107883-01H
4
5.  Always run heater with plaque control knob 
at the 1, 2, 3 or 4 locked positions. Never 
set control knob between locked positions. 
Poor combustion and higher levels of carbon 
monoxide may result.
6.  This heater needs fresh, outside air ventilation 
to run properly. This heater has an Oxygen 
Depletion  Sensing  (ODS)  safety  shutoff 
system. The ODS shuts down the heater if 
not enough fresh air is available. See Air for 
Combustion and Ventilation, page 5.
7.  Keep all air openings in front and bottom of 
heater clear and free of debris. This will insure 
enough air for proper combustion. 
8.  If heater shuts off, do not relight until you 
provide  fresh,  outside  air.  If  heater  keeps 
shutting off, have it serviced.
9.  Do not run heater
• where flammable liquids or vapors are used 
or stored
• under dusty conditions
10.  Do not use heater if any part has been under 
water. Immediately call a qualified service 
technician to inspect the room heater and to 
replace any part of the control system and any 
gas control which has been under water. 
11.  Turn off and unplug heater and let cool before 
servicing.  Only  a  qualified  service  person 
should service and repair heater. 
12.  Operating heater above elevations of 4,500 
feet could cause pilot outage.
13.  To prevent performance problems, do not use 
propane/LP fuel tank of less than 100 lbs. 
capacity.
14.  Before  using  furniture  polish,  wax,  carpet 
cleaner or similar products, turn heater off. If 
heated, the vapors from these products may 
create a white powder residue within burner 
box or on adjacent walls or furniture.
15.  Provide adequate clearances around air openings.
LOCAL CODES
Install and use heater with care. Follow all local codes. In 
the absence of local codes, use the latest edition of The 
National Fuel Gas Code, ANSI Z223.1/NFPA 54*.
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
SAFETY INFORMATION
Continued
Figure 1 - Vent-Free Gas Heater
Control Knob & Ignitor Button 
(not seen from this view)
Heater
Cabinet
Front 
Panel
Plaque
Grill
Guard
UNPACKING
1.  Remove heater from carton.
2.  Remove all protective packaging applied to 
heater for shipment.
3.  Check  heater  for  any  shipping  damage.  If 
heater is damaged, promptly return to where 
you bought heater.
PRODUCT FEATURES
SAFETY DEVICE
This heater has a pilot with an Oxygen Deple-
tion Sensing (ODS) safety shutoff system. The 
ODS/pilot is a required feature for vent-free room 
heaters. The ODS/pilot shuts off the heater if there 
is not enough fresh air.
IGNITION SYSTEM
This heater has either a piezo ignitor or electronic 
ignitor to light heater fuel supply.
THERMOSTATIC HEAT CONTROL
(Thermostat Models Only)
Thermostat  models  have  a  thermostat  sensing 
bulb and a control valve. This results in the great-
est heater comfort. This can also result in lower 
gas bills.
PRODUCT 
IDENTIFICATION