AIR FOR COMBUSTION 
AND VENTILATION
Continued
Ventilation Air From Outdoors
Provide extra fresh air by using ventilation grills or 
ducts. You must provide two permanent openings: 
one within 12” of the ceiling and one within 12” 
of the floor. Connect these items directly to the 
outdoors or spaces open to the outdoors. These 
spaces include attics and crawl spaces. Follow the 
National Fuel Gas Code, ANSI Z223.1/NFPA 54, 
Section 5.3, Air for Combustion and Ventilation for 
required size of ventilation grills or ducts. 
IMPORTANT:
 Do not provide openings for inlet 
or outlet air into attic if attic has a thermostat-
controlled power vent. Heated air entering the attic 
will activate the power vent.
Figure 3 - Ventilation Air from Outdoors
Outlet
Air
Ventilated
Attic 
Outlet
Air
Inlet
Air
Inlet Air
Ventilated 
Crawl Space
To 
Crawl
Space
To Attic
INSTALLATION
NOTICE: This heater is intended 
for  use  as  supplemental  heat. 
Use this heater along with your 
primary heating system. Do not 
install  this  heater  as  your  pri-
mary heat source. If you have a 
central heating system, you may 
run system’s circulating blower 
while using heater. This will help 
circulate the heat throughout the 
house. In the event of a power 
outage, you can use this heater 
as your primary heat source.
 WARNING: A qualified ser-
vice person must install heater. 
Follow all local codes.
CHECK GAS TYPE
Use only the correct type of gas (natural or pro-
pane/LP). If your gas supply is not the correct gas 
type, do not install heater. Call dealer where you 
bought heater for proper type heater.
  WARNING:  This  appliance 
is equipped for (natural or pro-
pane/LP) gas. Field conversion 
is not permitted.
INSTALLATION ITEMS
Before installing heater, make sure you have the 
items listed below.
•  for propane/LP gas, external regulator (supplied 
by installer)
•  piping (check local codes)
•  sealant (resistant to propane/LP gas)
•  equipment shutoff valve *
•  ground joint union
•  sediment trap
•  tee joint
•  pipe wrench
•  for natural gas, test gauge connection*
*  A CSA design-certified equipment shutoff valve 
with 1/8" NPT tap is an acceptable alternative to 
test gauge connection. The optional CSA design-
certified equipment shutoff valve can be purchased 
from your dealer. See Accessories, page 23.
LOCATING HEATER
  WARNING:  Maintain  the 
minimum  clearances  shown 
in Figure 4. If you can, provide 
greater  clearances  from  floor, 
ceiling and joining wall.
Minimum
From
Sides Of
Heater
36"
2"
FLOOR
CEILING
Minimum
Minimum To
Top Surface
Of Carpeting,
Tile Or Other
Combustible
Material
Left
Side
Right
Side
10"
Figure 4 - Mounting Clearances As 
Viewed From Front of Heater