Graco ti25442a ユーザーズマニュアル

ページ / 50
Setting
Setting
Setting Up
Up
Up the
the
the Equipment
Equipment
Equipment
1.
Disconnect the abrasive hose at the cam and
groove with the abrasive ball valve closed.
NOTE:
NOTE:
NOTE: If the pot contains water and abrasive
(especially under pressure), releasing the cam
and groove with the ball valve open will cause an
unintentional release of abrasive.
2.
Flush water through the pot and out the
disconnected abrasive ball valve before filling the
pot with water and abrasive.
3.
Reconnect the abrasive hose.
4.
Disconnect the pump inlet hose and flush the
water tank to remove any remaining debris.
Reconnect the pump inlet hose.
5.
Fill the water tank only with fresh water, then
open the inlet ball valve.
6.
Close the rinse, dump, and abrasive ball valves.
7.
Turn the selector valve to RINSE.
8.
Disengage the Emergency Stop.
NOTE:
NOTE:
NOTE: The water pump will not work unless the
Emergency Stop is disengaged.
334666B
11