WARNING
When used without adequate combustion and ventilation air, heater 
may give off CARBON MONOXIDE, an odorless, poisonous gas.
Do not install heater until all necessary provisions are made for 
combustion and ventilation air. Consult the written instructions 
provided with the heater for information concerning combustion 
and ventilation air. In the absence of instructions, refer to the 
National Fuel Gas Code, ANSI Z223.1, Section 5.3 or applicable 
local codes.
This heater is equipped with a PILOT LIGHT SAFETY SYSTEM 
designed to turn off the heater if not enough fresh air is available.
DO NOT TAMPER WITH PILOT LIGHT SAFETY SYSTEM!
If heater shuts off, do not relight until you provide fresh air.
If heater keeps shutting off, have it serviced. Keep burner and control 
compartment clean.
CARBON MONOXIDE POISONING MAY LEAD TO DEATH.
Early signs of carbon monoxide poisoning resemble the flu, with 
headache, dizziness and/or nausea. If you have these signs, heater 
may not be working properly. Get fresh air at once! Have heater 
serviced.
Some people – pregnant women, persons with heart or lung disease, 
anemia, those under the influence of alcohol, those at high altitudes 
– are more affected by carbon monoxide than others.
The pilot light safety system senses the depletion of oxygen at its 
location. If this heater is installed in a structure having a high vertical 
dimension, the possibility exists that the oxygen supply at the higher 
levels will be less than that at the heater. In this type of application, 
a fan to circulate the structure air will minimize this effect. The use 
of this fan will also improve the comfort level in the structure. When 
a fan is used to circulate air, it should be located so that the air flow 
is not directed at the burner.
•  An unvented room heater having an input rating of more than 
6,000 Btu per hour shall not be installed in a bathroom
•  An unvented room heater having an input rating of more than 
10,000 Btu per hour shall not be installed in a bedroom or bath-
room.
•  Never burn solid fuels in a fireplace where a gas log set is in-
stalled.
•  Due to high temperatures, the appliance should be located out of 
traffic and away from furniture and draperies.
•  Do not place clothing or other flammable material on or near the 
appliance.
•  Children and adults should be alerted to the hazards of high sur-
face temperature and should stay away to avoid burns or clothing 
ignition.
•  Young children should be carefully supervised when they are in 
the same room as the appliance.
•  This unit complies with ANSI Z21.11.2 Unvented Heaters and it 
also complies with ANSI Z21.60 Decorative Vented Appliances for 
Solid Fuel Burning Fireplaces. State or local codes may only allow 
operation of this appliance in a vented configuration. Check your 
state or local codes.
•  Correct installation of logs, proper location of the heater and annual 
cleaning are necessary to avoid potential problems with sooting. 
Sooting, resulting from improper installation or operation, can 
settle on surfaces outside the fireplace.
•  Avoid any drafts that could alter burner flame patterns. Do not 
allow fans to blow directly into the fireplace. Do not place a blower 
inside burn box area of firebox. Ceiling fans may create drafts that 
alter burner flame patterns. Sooting and improper burning will 
occur as a result of drafts.
•  WARNING: Do not allow fans to blow directly into the fireplace. 
Avoid any drafts that alter burner flame patterns.
•  WARNING: Do not use a blower insert, heat exchanger insert or 
other accessory not approved for use with this heater.
•  Periodic examination and cleaning of the venting system of the 
solid-fuel burning fireplace, including frequency of such examination 
and cleaning, by a qualified agency.
•  The installation must conform with local codes or, in the absence 
of local codes, with the National Fuel Gas Code, ANSI Z223.1/
NFPA54.
•  NOTE: Installation and repair should be done by a qualified service 
person. The appliance should be inspected before use and at least 
annually by a qualified service person. More frequent cleaning may 
be required due to excessive lint from carpeting, bedding material, 
etc. It is imperative that the control compartment, burners and 
circulating air passageways of the appliance be kept clean.
•  Any safety screen or guard removed for servicing an appliance must 
be replaced prior to operating the appliance. Provide adequate 
combustion and ventilation air.
•  The flow of combustion and ventilation air MUST NOT be ob-
structed.
•  Provide adequate clearances around air openings into the combus-
tion chamber and adequate accessibility clearance for servicing 
and proper operation. NEVER obstruct the front opening of the 
appliance.
•  An unvented room heater intended for installation in a solid-fuel 
burning fireplace shall comply with the following instructions.
•  A fireplace screen must be in place when the appliance is operating 
and, unless other provisions for combustion air are provided, the 
screen  shall  have  an  opening(s)  for  introduction  of  combustion 
air.
•  Solid-fuels shall not be burned in a masonry or UL 127 factory-built 
fireplace in which an unvented room heater is installed.
•  Any  glass  doors  shall  be  fully  opened  when  the  appliance  is  in 
operation. 
•  Any outside air ducts and/or ash dumps in the fireplace shall be 
permanently closed at time of appliance installation.
•  WARNING:  Failure  to  keep  the  primary  air  opening(s)  of  the 
burner(s) clean may result in sooting and property damage.
•  WARNING: Before installing in a solid-fuel burning fireplace, the 
chimney flue and firebox must be cleaned of soot, creosote, ashes 
and loose paint by a qualified chimney cleaner.
IMPORTANT SAFETY INFORMATION