OPTIONAL POSITIONING OF THERMOSTAT SENSING BULB 
Thermostat 
Sensing 
Bulb
Gas Valve 
Assembly
Mounting 
Bracket
Figure 30 - Location of Gas Valve 
Assembly and Thermostat Sensing Bulb 
Figure 31 - Removing Thermostat 
Sensing Bulb
Thermostat Screw
Retaining 
Clamp
Thermostat 
Sensing 
Bulb
Capillary
FOR MASONRY AND FACTORY-
BUILT METAL FIREPLACE
If your log set cycles to pilot, but the room 
temperature  drops  to  a  lower  than  ideal 
comfort level before the log set comes back 
on, you may want to reposition the thermostat 
sensing bulb.
The thermostat sensing bulb is located on the 
gas valve assembly. This location allows the 
thermostat to keep the room temperature at 
an ideal comfort level for most fireplace appli-
cations. If positioning the thermostat sensing 
bulb elsewhere, follow these directions.
Tools needed: 5/16" hex driver or socket
1.  Locate the gas valve assembly and ther-
mostat sensing bulb (see Figure 30).
2.  With  5/16”  hex  driver  or  socket,  loosen 
the thermostat screw. Carefully slide the 
thermostat sensing bulb out of the retain-
ing clamp (see Figure 31).
 
Note: Do not remove screw. Make sure 
you tighten screw after removing thermo-
stat sensing bulb.
 
IMPORTANT: Do not force or bend ther-
mostat sensing bulb or capillary.
3.  The thermostat sensing bulb may be 
located  to  the  lower  right  front  side  of 
fireplace. Place bulb in an area that will 
be close to room temperature when log 
set is operating