adjustments  may  be  necessary.  This  is  dependent  upon  your
individual home construction, refer to the “Operation Guide” (Table 1).
Your  Aprilaire  Automatic  Humidifier,  is  a  high  precision  system
that  will  accurately  maintain  the  relative  humidity  in  your  home.
For  every  1º  change  in  outdoor  temperature,  the  control  will
automatically  adjust  the  indoor  relative  humidity  (RH)  by 
1
/
2
%. 
If  you  would  like  to  determine  the  RH  in  your  home,  follow 
these steps:
1. Determine the outdoor temperature.
2.  Activate  the  furnace  blower  by  setting  your  thermostat  fan
switch  to  the  “On”  position,  or  setting  your  thermostat  to  a
higher temperature.
3. Turn the control dial setting to the “Off” position. Then, slowly
turn the dial clockwise until you hear the solenoid valve “click
on.” Next, slowly turn the dial counter clockwise until you hear
the  solenoid  valve  “click  off.”  At  this  point,  make  note  of  the
dial setting.
4. Locate your dial setting on Table 2. Follow the dial setting to
the  right  until  it  intersects  with  the  current  outdoor
temperature. This is the relative humidity in your home under
existing conditions.
5. Return the thermostat and the control to their original settings.
The  Automatic  Humidifier  will  accurately  control  the  humidity  in
your home to a maximum of 45% RH and a minimum of 10% RH.
The  values  of  outdoor  temperature  and  dial  settings  may  fall  in
- 5 -
Off
7
6
5
4
3
2
1
Te
st
N
O
R
M
A
L
Automatic Mode
(Figure A)
The  relative  humidity  in
your  home  will  now  be
accurately  controlled  to
meet your needs and should
not  need  further  adjustment
during 
future 
heating
seasons.  Make  note  of  the
dial setting in the event you
temporarily  move  the  knob
when  performing  annual
maintenance of the Aprilaire
Humidifier