Monte Carlo Fan Company 5EPR60BRD Series ユーザーズマニュアル

ページ / 8
Place ball on downrod. Replace pin
removed earlier and pull ball up so that
the pin fits in the notches in the ball.
19
Tighten set screw to hold ball in
place.
20
Attach blade arms to blades using
the blade arm screws and washers
provided.
28
Check the motor for plastic shipping sta-
bilizer tabs and remove if they are pres-
ent. The screws, washers and motor pads
are pre-installed to the blade holders.
Attach blade assembly to motor and
tighten screws securely.
29
Loosen 2 screws and remove 1
screw. Save screw removed. 
30
Raise fan with downrod assembled to
the ceiling bracket and hang fan
assembly. Be sure to rotate the
downrod ball so that the notch in the
bracket engages the slot in the ball.
22
Set dip switches on the Remote Transmitter and Remote
Receiver to the same settings.  This must be done so the
units will communcate properly.  If you have other fans you
can set to control from one transmitter by setting both
receivers the same as the transmitter.  If you have more
than one fan with remote.  You can set the dip switches to
different positiosns to have seperate control.
Remote Transmitter Dip swtiches
Remote Receiver Dip switches
21
Install remote receiver by sliding into opening in
the Mounting bracket.  Make sure that the dip
switches on the Transmitter and the Receiver
are set to the same position.  See Fig 42 for
remote operation
24
Fan and light kit combinations over 35 lbs,
in both flush and downrod mode the safety
cable must be installed into the house struc-
ture beams using the 3” lag screws,washers,
and lock washers. provided.  Make sure that
when the safety cable is fully extended the
lead wires are longer than the cable and no
stress is placed on the lead wires. 
23
Safety cable installation
Safety Cable
Lag Screw
safety
cable
3” lag
screw
lock
washer
washer
Make wire connections to power source using
wire nuts provided.  Make sure that no filiments
are outside of the wirenut. After making the
wire connections, the wires should be spread
apart with the grounded conductor and the
equipment-grounding conductor on one side of
the outlet box and ungrounded conductor on
the other side of the outlet box.
26
Lift canopy to ceiling aligning the key hole slots
with the screws on the bottom of the mounting
bracket.  Rotate the canopy counter clockwise
to lock in place.  Tighten the screws to secure
the canopy.  See inset for keyhole shape
27
Make wiring connections as indicated above.
White from fan to white from remote marked
N. Blue from fan to blue from remote marked
light. Black from fan to Black from remote
marked L. White from house to white from
remote marked AC N . Black from house to
Black from remote marked AC L. Connect all
green ground wires to Ground wire from
House.
white
black
25