Monte Carlo Fan Company 5ML52 ユーザーズマニュアル

ページ / 4
5ML52-CUL-ENG
Insert downrod into motor yoke. Next, insert
clevis pin through yoke and downrod and
secure with cotter pin. (see inset)
Installation work and electrical wiring must be done by qualified person(s) in accordance with  applicable codes and standards
(ANSI/NFPA 70-1999), including fire-rated construction.
Use this unit only in the manner intended by the manufacturer.  If you have  any questions contact the manufacturer.
After making the wire connections, the wires should be spread apart with the grounded conductor and the equipment-grounding con-
ductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box.
Before you begin installing the fan, Switch power off at Service panel and lock service disconnecting means to prevent power from being
switched on accidentally.  When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such
as a tag, to the service panel.
Be cautious! read all instructions and safety information before installing your new fan. Review the accompanying assembly diagrams.
When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
Make sure the installation site you choose allows the fan blades to rotate without any obstructions. Allow a minimum clearance of 7 feet
from the floor to the trailing edge of the blade.
To reduce the risk of fire, electric shock, or personal injury, mount to outlet box or supporting system acceptable for fan support. 
(Mounting must support at least 35 lbs.)
Do not bend blade holders during installation to motor, balancing or during cleaning.  Do not insert foreign object between rotating
blades.
Attach the mounting bracket using only the hardware supplied with the outlet box.
To reduce the risk of fire or electric shock, do not use this fan with any solid state fan speed control device, or variable speed control.
If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application.
NEVER place a switch where it can be reached from a tub or shower.
The combustion airflow needed for safe operation of fuel-burning equipment may be affected by this unit’s operation. Follow the heating
equipment manufacturer’s guideline safety standards such as those published by the National Fire Protection Association (NFPA), and
the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.
Before servicing or cleaning unit, Switch power off at Service panel and lock service disconnecting means to prevent power from being
switched on accidentally.  When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such
as a tag, to the service panel.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
Installation
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS,
OBSERVE THE FOLLOWING: READ AND SAVE THESE INSTRUCTIONS
S
AFETY
T
IPS
TOOLS REQUIRED
Phillips Screwdriver      Wire Cutters       Pliers      Step Ladder
Before you begin installing the fan, Switch power off
at Service panel and lock service disconnecting means
to prevent power from being switched on accidentally.
When the service disconnecting means cannot be
locked, securely fasten a prominent warning device,
such  as a tag, to the service panel.
Before installing this fan make sure the outlet
box is properly installed to the house structure.
To reduce the risk of fire, electric shock, or per-
sonal injury, mount to outlet box or supporting
system acceptable for fan support. 
(Mounting must support at least 35 lbs.)
Install  the Mountiing Bracket to the Outlet box.
Use only the screws provided with the out-
let box.  
Install canopy and yoke cover over the down-
rod.
3
2
1
4
6
Thread wire through downrod with canopy and
yoke cover assembled.
5