Error
02
03
10
11
12
Faulty
No burner operation during 
freeze protection mode
Power interruption during 
Bath fill (Water will not flow 
when power returns).
Air Supply or Exhaust 
Blockage
No Ignition
Flame Failure
Remedy
Service Call
Turn off all hot water taps. Press ON/OFF twice.
Ensure Rinnai approved venting materials are being used.  
Check that nothing is blocking the flue inlet or exhaust.   
Check all vent components for proper connections.   
Ensure vent length is within limits.
Ensure condensation collar was installed correctly.     
Verify dip switches are set properly.  
Check fan for blockage.    
Check that the gas is turned on at the water heater, gas meter, or cylinder. 
Ensure gas type and pressure is correct. 
Ensure gas line, meter, and/or regulator is sized properly.
Bleed all air from gas lines.
Verify dip switches are set properly. 
Ensure appliance is properly grounded.
Disconnect all MSA controls.
Ensure igniter is operational.
Check igniter wiring harness for damage. 
Check gas solenoid valves for open or short circuits.
Remove burner cover and ensure all burners are properly seated.  
Remove burner plate and inspect burner surface for condensation or debris.
Check that the gas is turned on at the water heater and gas meter. Check for obstructions in the flue 
outlet.
Ensure gas line, meter, and/or regulator is sized properly.
Ensure gas type and pressure is correct.
Bleed all air from gas lines.
Ensure proper Rinnai venting material was installed.
Ensure condensation collar was installed properly.
Ensure vent length is within limits.
Verify dip switches are set properly.
Ensure appliance is properly grounded.
Disconnect keypad. 
Disconnect all MSA controls if installed. 
Check power supply for loose connections. 
Check power supply for proper voltage and voltage drops.
Ensure flame rod wire is connected.
Check flame rod for carbon build-up.
Disconnect and re-connect all wiring harnesses on unit and PC board.
Check all components for electrical short.
Check gas solenoid valves for open or short circuits.
Remove burner plate and inspect burner surface for condensation or debris.
Failure to remedy faults may result in severe burns, scalds, and/or 
death.
1
Rinnai America
FF  Models
E R R O R   M E S S A G E S
The  Rinnai  Water  Heater  has  the  ability  to  check  its  own  operation  continuously.  If  a  fault 
occurs,  an  Error  Message  will  flash  on  the  Digital  Dispaly  of  the  Remote  Controller. This  assists 
with  diagnosing  the  fault,  and  may  enable  you  to  overcome  a  problem  without  a  service  call. 
Please  identify  the  code  displayed  when  inquiring  about  service.