M A I N T E N A N C E  &  S E R V I C E  I N F O R M A T I O N
MAINTENANCE  SUGGESTIONS
This  water  heater  has  been  designed  and  constructed 
for  a  long  performance  life  when  installed  and  operated 
properly  under  normal  conditions.  Regular  inspections, 
as  outlined  in  this  section,  are  strongly  recommended 
as  a  means  of  keeping  your  heater  operating  efficiently. 
Consideration  should  be  given  to  periodic  maintenance 
of  scale  removal  in  applications  where  the  water 
hardness  quality  is  elevated  and  the  water  heater 
runs  for  extended  periods  such  as  in  commercial 
applications  or  applications  with  circulating  loops.
1.  Cleaning 
The  water  heater  should  be  cleaned  annually. 
Keep  the  water  heater  clear  of  dust  and  debris 
especially  in  and  around  burner. 
Cleaning  procedures  for  the  Rinnai  Water  Heater 
are  as  follows: 
1)  Turn  off  and  disconnect  electrical  power. Allow 
to  cool  for  one  hour. 
2)   Remove  the  Front  Panel  by  removing  screws. 
See  parts  breakdown  on  panels. 
3)   Use  pressurized  air  to  remove  dust  from  around 
main  burner. 
4)   Use  soft  dry  cloth  to  wipe  cabinet. 
DO  NOT  DAMAGE  OR  DISTORT ANY  PARTS 
OF  HEATER. 
DO  NOT  USE  WET  CLOTH  OR  SPRAY 
CLEANERS  ON  BURNER.
 
2.  Visual  check  of  main  burner  flames. 
The  burner  must  flame  evenly  over  the  entire 
surface  when  operating  correctly. The  flame  must 
burn  with  a  clear,  blue,  stable  flame.  See  the  parts 
breakdown  of  the  burner  for  the  location  of  view 
ports. Any  and  all  parts  removed  for  inspection  or 
service  must  be  replaced  before  operating  the  unit.
The  flame  pattern  should  be  as  shown  in  the 
following  Figures. 
*  VENT  MAINTENANCE 
*  VENT  SYSTEM
 
Must  be  checked  annually  for 
blockage  or  deterioration.  See 
vent  installation  instructions. 
*  MAINTENANCE-ELECTRIC 
MOTORS
 
Motors  are  permanently 
lubricated  and  need  no 
lubrication.  Keep  fan  and  motor 
free  of  dust  and  dirt,  clean 