Normal Heater Operation
• Press the Heat ON / OFF button. 
• The ON/Combustion indicator illuminates green, and the convection motor starts 
pre-purging. 
• The Digital Display displays the present room temperature. After approximately 3 seconds, the
electrode starts discharging electricity, and at the same time, the solenoid valves and the
modulating valve open. After ignition, while the main burner is on “High”, the ON/Combustion
indicator illuminates red when the thermocouple detects the flame, and electrical discharge
ceases. (Forced combustion is carried out for approx. 60 sec on High). 
• The PCB’s micro-computer regulates the room temperature and combustion time, and also con-
trols both using fuzzy logic until the preset room temperature is reached.
Temperature Control
• Room temperature can be adjusted as desired with the Temp / Time buttons. 
Turning OFF the Heater
• Press the Heat ON / OFF button.
• The solenoids and modulating valve close and combustion ceases. 
• The indicators will go out. (The digital display will show the present time.)
• The convection motor stops after post-purging (2~4 minutes).
Child Lock
• Press the Up and Down buttons simultaneously. The Child Lock indicator will illuminate.
• When setting the lock while heater is operating, only the Heat ON/OFF button responds. When
unit is off, the Heater ON /OFF button will not respond. (The Air Purifier can be operated.)
• The Up and Down buttons should be pressed simultaneously for approximately 2 seconds to
cancel the Child Lock.
Clock Setting
• Press the Set Times button once. The Clock indicator will flash.
• Press the Temp/Time buttons to adjust the time.
• Press the Set Times button five times to set the clock. The indicator will go out.
Setting Timers 1 and 2 (Heater)
• Press the Set Times button twice. Timer 1 “on” indicator will flash.
• Press the Temp/Time buttons to adjust to the starting time.
• Press the Set Times button again. The Timer 1 “off” indicator will flash.
• Press the Temp/Time buttons to adjust to the finishing time.
• Press the Set Times button three times to lock in the programmed times. The Digital Display will
show the current time. (The Timers can also be set during heater operation. In this instance,
combustion will cease and the Timer will go into stand-by mode. When in stand-by mode, the
set room temperature for the Timers cannot be modified. In order to modify the set room
temperature, revert the unit to its normal state, modify the set room temperature and press the
Timer button to complete setting.)
• The intelligent function will start the unit so that the room is warm at the set time.
• The Timer operates for the set time then automatically stops. (The Timer indicator starts flashing
5 minutes before the unit ceases operation and continues to flash after operation has ceased.)
• If the same button is pressed twice when the Timer is in stand-by mode, the unit will go into
normal OFF mode.