Rinnai RCE-560PTR ユーザーズマニュアル

ページ / 71
Convector 460/560PTR
- 25 -
©Rinnai
10.  Operational Flow Chart
Heater ON
Power Point ON
I
II
ON/OFF SW.
Normal
No
Yes
No
No
Yes
ON/OFF sw.  ON
Yes
Operation/Comb. Ind.
Illuminates (Green)
Display time6Room temp.
A
R.F detection
sw.temp. fuse
Normal
III
T/C output
<10mV
No
No
No
Yes
Yes
Conv. motor  Hi   ON
Conv. motor Lo  ON
Yes
Sparker    ON
Solenoid SV1 ON
Solenoid SV2 ON
POV Med  ON
(After 0.2 sec)
Overheat TH
Normal
Room Temp.
Thermistor 
Normal
POV  Hi  ON
Yes
No
No
Yes
T/C output
(Ú1mV)
Operation/Comb. Indic.
Illuminates (Red)
Conv. motor med  ON
Sparker   OFF
Conv. motor Hi  ON
Rev. flame detection
sw. OFF (150EC)
No
Yes
2
Temp. check starts
C.M. Mod. control
 M.V modulating. control
OH Thermistor
activates (65EC)
Filter indicator flashes
Safety device
activated
No
No
Yes
(after approx. 3 sec.)
(30 sec. after (b)) 
(10 sec. after (c))
Ú
1 Igniton sensed
output is the initial T/C
check output +2mV
(min.3mV. max. 18mV)
Fan motor error
<350rpm, 4 sec)
B
C.M med ON
Sparker    OFF
Sparker    OFF
Sparker    OFF
(a)
(c)
73
Operation/Comb.
Ind. flashes (red)
71
Operation/Comb.
Ind. flashes (red)
70
Operation/Comb.
Ind. flashes (red)
14
Operation/Comb.
Ind. flashes (red)
Filter Ind. flashes
03
Operation/Comb.
Ind. flashes (red)
72
Operation/Comb.
Ind. flashes (red)
(After a max. of  50 sec)
33
Operation/Comb.
Ind. flashes (red)
34
31
Operation/Comb.
Ind. flashes (red)
32
Operation/Comb.
Ind. flashes (red)
11
62
Operation/Comb.
Ind. flashes (red)
12
Cause eliminated
Power Point OFF
All indicators OFF
ON/OFF Switch OFF
C.M.   OFF
C.M.   OFF
(After max.255 sec)
(Disconnection)
(Short circuit)
C.M. med  ON
SV1,SV2 OFF
POV  OFF
(Disconnection)
(Short circuit)
Conv. motor OFF
C.M. med OFF
SV1,SV2  OFF
POV  OFF
(After 5 sec)
SV1, SV2  OFF
POV  OFF
Conv. motor OFF
(150~255 sec)
14
Operation/Comb.
Ind. flashes (red)
Filter Ind. flashes
Thermal fuse
discon. (216EC)
OH thermistor
activated (70EC)
Gas disconn. device
when tilting is
activated (50~80EC)
03
Operation/Comb.
Ind. flashes (red)
Incomplete comb.
prevention safety
device is activated
(*mV, 5 sec)
12
Operation/Comb.
Ind. flashes (red)
OFF Function act.
 >40EC 10 min
16
Operation/Comb.
Ind. flashes (red)
ON/OFF switch
 Error (for 15 sec)
70
Operation/Comb.
Ind. flashes (red)
Re-instatement
of power
00
Operation/Comb.
Ind. flashes (red)
Power failure
Operation ceases
C.M Med ON
SV1, SV2  OFF
M.V POV  OFF
C.M. med  ON
LPG
NG
 I: Micro-computer and E2PROM's signal path normal
 II: Solenoid valve and Modulation valve rotation normal
 III: Gas disconnection device normal when tilting
 C.M.: Convection Motor
 R.F.: Reverse Flame
 SV: Solenoid
1
2
3
4
5
Fan motor
>6 r.p.m
6
62
Operation/Comb.
Ind. flashes (red)
10
11
9
5
5
PROP.G
5
9
2
10
3
12
11
1
Yes
(10 sec after (a))
C.M.   OFF
No
Yes
5
7
8
8
9
(b)
16mV
14mV
16mV
*