Memory Function for Maintenance Data
The 5 most recent error messages and the estimated time of combustion, combustion frequency,
estimated time of air purifier operation, and air purifier operation time are stored, as well as E
2
PROM.
<How to recall data>
While the unit is off, press the “override” and “
∨” buttons simultaneously for at least 2.5 seconds to
bring up the error history on the display. The error history will display the following in a 2.5 second
cycle : the 5 most recent error messages (the most recent is No. 1; No.5 the oldest), estimated time
of combustion, combustion frequency, estimated time of air purifier operation, and air purifier
operation time.
Example.
<How to Reset> (Same as Initialisation of E
2
 PROM)
• While the unit is OFF, press all three buttons “
∧”, “∨”, and “override” simultaneously for at least
2.5 seconds.
• The digital display will go out, and “88:88” will be displayed when resetting has been com-
pleted, then “--:--” will be displayed.
(Additional combustion time, combustion rpm, and additional air purifier operation time will not be
reset.)
Note 1: This operation time will be displayed as the actual operation time after initialisation when
the reset button is pressed.
Item
Digital Display
Comments
Error History 
No. 1 (Latest Error)
Sudden Extinction
No. 2
Power Failure
No. 3
Mis-ignition
No. 4
Mis-ignition
No. 5
No error
Combustion Time
1300 hours
Not displayed if below 100 hours
Combustion Frequency
3700 times
Not displayed if below 100 times
Estimated Air Purifier Opera-
tion Time
5000 hours
Not displayed if below 100 hours
Air Purifier Operation Time
Note 1
5000 hours
Not displayed if below 100 hours