Rinnai RCE-560PTR ユーザーズマニュアル

ページ / 71
Convector 460/560PTR
- 50 -
©Rinnai
7. Removal of the Surge Protector and 
Sparker Unit
CAUTION
240 Volt exposure. Isolate the electrical supply to 
the appliance and reconfirm with the neon 
screwdriver or multimeter.
a. Follow section 3 (Removal of the Front 
Panel).
b. Remove two (2) screws from the surge pro-
tector sparker unit bracket.
c. Lift from bracket
d. Disconnect all leads.
e. Disconnect sparker unit from PCB and sole-
noid loom. (Note: the sparker unit comes 
complete with wiring loom for solenoids as 
shown below.)
8. Removal of the Overheat Switch
CAUTION
240 Volt exposure. Isolate the electrical supply to 
the appliance and reconfirm with the neon 
screwdriver or multimeter.
a. Follow section 3 (Removal of the Front 
Panel).
b. Remove surge protector/sparker assy 
c. Remove the two (2) screws from the OHS.
9. Removal of the Thermocouple
CAUTION
240 Volt exposure. Isolate the electrical supply to 
the appliance and reconfirm with the neon 
screwdriver or multimeter.
a. Follow section 3 (Removal of the Front 
Panel).
b. Remove one (1) screw securing the cover 
plate
c. Lift and remove bracket (2 screws).